Electroanalytical and chromatographic determination of pentachlorophenol and related molecules in a contaminated soil: a real case example

被引:36
作者
Codognoto, L
Zuin, V
de Souza, D
Yariwake, JH
Machado, SAS
Avaca, LA
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, Grp Mat Eletroquim & Metodos Eletroanalit, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Sao Paulo, Inst Quim Sao Carlos, Grp Anal Fitoquim, BR-13656097 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
pentachlorophenol; soil contamination; liquid chromatography; electroanalysis; diamond electrodes; ultramicroelectrodes;
D O I
10.1016/j.microc.2004.02.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electroanalytical and chromatographic methodologies have been applied for the determination of pentachlorophenol (PCP) and some of its derivatives in real soil samples contaminated by industrial discharge. The analytes were extracted with hexane from soil samples collected at different points of the site and mixed to produce a representative sample. Square wave voltammetry (SWV) experiments were carried out on either a boron-doped diamond (BDD) electrode or a gold ultramicroelectrode (Au-UME) in an analyte composed by the Britton-Robinson (B-R) buffer at pH 5.5 with the direct addition of proper amounts of the extract. The voltammetric responses revealed an irreversible anodic peak at approximately 0.80 V vs. Ag/AgCl with a peak current showing a linear dependence on PCP concentration. This linear relationship yielded a detection limit (DL) of 2 X 10(-8) mol l(-1) (or 5.5 mug l(-1)) for the BDD electrode and 6.9 x 10(-8) mol l(-1) (18.4 mug l(-1)) for the Au-UME, while the independently measured HPLC detection limit was 1.1 x 10(-8) mol l(-1) (3.0 mug l(-1)). The application of electroanalytical and chromatographic methodologies in the analysis of soil extracts revealed, besides the PCP responses, signals for some related molecules such as o-tetrachlorobenzoquinone (o-chloranil), hexachlorobenzene and tetrachlorophenol. Recovering experiments for PCP showed a concentration of 27.5 mg kg(-1) for the electroanalytical determinations and 26.8 mg kg(-1) for the HPLC analysis, values exceedingly high if considering that the maximum residue limit established for natural waters by the Brazilian Environmental Agency is 10 mug l(-1). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 31 条
  • [1] AIROLDI FPS, 1999, REV BRAS TOXICOL, V12, P5
  • [2] BARRIO MAR, 1992, FRESEN J ANAL CHEM, V344, P34
  • [3] Universal buffer soluttons and the association constant of veronal
    Britton, HTS
    Robinson, RA
    [J]. JOURNAL OF THE CHEMICAL SOCIETY, 1931, : 1456 - 1462
  • [4] Square wave voltammetry on boron-doped diamond electrodes for analytical determinations
    Codognoto, L
    Machado, SAS
    Avaca, LA
    [J]. DIAMOND AND RELATED MATERIALS, 2002, 11 (09) : 1670 - 1675
  • [5] IUPAC REPORTS ON PESTICIDES .14. ENVIRONMENTAL CHEMISTRY OF PENTACHLOROPHENOL
    CROSBY, DG
    [J]. PURE AND APPLIED CHEMISTRY, 1981, 53 (05) : 1051 - 1080
  • [6] Electroanalytical study of the paraquat herbicide in aqueous solution by square wave voltammetry using ultramicroelectrodes.
    de Souza, D
    Machado, SAS
    [J]. QUIMICA NOVA, 2003, 26 (05): : 644 - 647
  • [7] Diserens JM, 2001, J AOAC INT, V84, P853
  • [8] Electroanalysis of dopamine and NADH at conductive diamond electrodes
    Fujishima, A
    Rao, TN
    Popa, E
    Sarada, BV
    Yagi, I
    Tryk, DA
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 473 (1-2) : 179 - 185
  • [9] Simultaneous determination of chlorophenols, chlorobenzenes and chlorobenzoates in microbial solutions using pentafluorobenzylbromide derivatization and analysis by gas chromatography with electron-capture detection
    Gabelish, CL
    Crisp, P
    Schneider, RP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 749 (1-2) : 165 - 171
  • [10] Gandini D, 1999, NEW DIAM FRONT C TEC, V9, P303