Electroanalytical study of the paraquat herbicide in aqueous solution by square wave voltammetry using ultramicroelectrodes.

被引:25
作者
de Souza, D [1 ]
Machado, SAS [1 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
来源
QUIMICA NOVA | 2003年 / 26卷 / 05期
关键词
square wave voltammetry; paraquat; ultramicroelectrodes;
D O I
10.1590/S0100-40422003000500004
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
ELECTROANALYTICAL STUDY OF THE PARAQUAT HERBICIDE IN AQUEOUS SOLUTION BY SQUARE WAVE VOLTAMMETRY USING ULTRAMICROELECTRODES. The electrochemical behavior of paraquat on Pt, Au and carbon fiber ultrainicroelectrodes were studied in laboratory samples by square wave voltammetry at high frequencies. The results showed two reversible peaks for paraquat reduction, in agreement to the literature data. The first peak was associated to the reduction of paraquat molecule in solution, with the further adsorption of the intermediate on the electrode surface. This adsorbed species undergoes to electroreduction in a reaction associated to the second voltammetric peak. The variation in pH and square wave parameters showed the best conditions to reduce paraquat as pH 5.0, frequency as high as 1000 s(-1), scan increment of 2 mV and square wave amplitude of 50 mV. At such conditions, a variation of paraquat concentrations from 4.3 x 10-(6) to 1.66 x 10-(4) mol L-1 presented values for the detection limit equal to 3.9, 6.2 and 20.3 ppb on Pt, Au and carbon, respectively, at 1000 s-1. These values are quite below(17) the allowed limit of paraquat in drinking water.
引用
收藏
页码:644 / 647
页数:4
相关论文
共 16 条
  • [1] Determination of linuron in soil by stripping voltammetry with a carbon fiber microelectrode
    de la Huebra, MJG
    Hernández, P
    Ballesteros, Y
    Hernández, L
    [J]. TALANTA, 2001, 54 (06) : 1077 - 1085
  • [2] Square wave voltammetry. Part 1: Theoretical aspects.
    de Souza, D
    Machado, SAS
    Avaca, LA
    [J]. QUIMICA NOVA, 2003, 26 (01): : 81 - 89
  • [3] Application of carbon fibre microelectrode for studying the impact of pesticides on a frog's egg
    Fung, YS
    Mak, JLL
    [J]. ELECTROCHIMICA ACTA, 1999, 44 (21-22) : 3855 - 3864
  • [4] KLAASSEN CD, 1989, TOXICOLOGY BASIC SCI
  • [5] Electrocatalytic determination of paraquat using a nafion film coated glassy carbon electrode
    Lu, TH
    Sun, IW
    [J]. TALANTA, 2000, 53 (02) : 443 - 451
  • [6] Electrochemical behaviour of methyl viologen in a matrix of paper
    Monk, PMS
    Turner, C
    Akhtar, SP
    [J]. ELECTROCHIMICA ACTA, 1999, 44 (26) : 4817 - 4826
  • [7] NUWER MJ, 1998, ANAL CHIM ACTA, V362, P3
  • [8] OSTERYOUNG J, 1991, MICROELECTRODES THEO
  • [9] SQUARE-WAVE VOLTAMMETRY
    OSTERYOUNG, JG
    OSTERYOUNG, RA
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (01) : A101 - &
  • [10] A sensitive determination of paraquat by spectrophotometry
    Rai, MK
    Das, JV
    Gupta, VK
    [J]. TALANTA, 1997, 45 (02) : 343 - 348