Electrocatalytic determination of paraquat using a nafion film coated glassy carbon electrode

被引:53
作者
Lu, TH [1 ]
Sun, IW [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Chem, Tainan 70101, Taiwan
关键词
paraquat; determination; nafion; electrocatalytic; differential pulse voltammetry;
D O I
10.1016/S0039-9140(00)00511-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nafion film coated glassy carbon electrode (NFGCE) was employed for the determination of paraquat. Paraquat was accumulated onto NFGCE by the cation-exchange feature of nafion at open circuit potential in basic medium followed by cathodic differential pulse voltammetric (CDPV) determination in a medium containing permanganate ions. The sensitivity for the determination of paraquat was improved through the electrocatalytic reduction of permanganate by the reduced paraquat. With 3-min accumulation, the analytical signal versus concentration dependence was linear from 1.0 to 100 ppb with a detection limit of 0.5 ppb. The interference from common metal ions was minimized by addition of ethylenediaminetetraacetate (EDTA) into the sample solution. The use of nafion also improves the resistance to interference from surfactants. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:443 / 451
页数:9
相关论文
共 27 条
  • [1] AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF PARAQUAT AT THE SUBNANOGRAM PER MILLILITER LEVEL
    AGUDO, M
    RIOS, A
    VALCARCEL, M
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (01) : 103 - 109
  • [2] AHMAD I, 1983, J ASSOC OFF ANA CHEM, V66, P663
  • [3] Aldrich AP, 1998, ELECTROANAL, V10, P369, DOI 10.1002/(SICI)1521-4109(199805)10:6<369::AID-ELAN369>3.0.CO
  • [4] 2-W
  • [5] CATHODIC STRIPPING VOLTAMMETRY OF PARAQUAT ON A CARBON PASTE ELECTRODE ELECTRODE MODIFIED WITH AMBERLITE XAD-2 RESIN
    ALVAREZ, E
    SEVILLA, MT
    PINILLA, JM
    HERNANDEZ, L
    [J]. ANALYTICA CHIMICA ACTA, 1992, 260 (01) : 19 - 23
  • [6] ELECTROCHEMICAL-BEHAVIOR OF CLAY MODIFIED ELECTRODES IN THE PRESENCE OF CATIONIC SURFACTANT
    BRAHIMI, B
    LABBE, P
    REVERDY, G
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 267 (1-2): : 343 - 349
  • [7] EMERGENCY ANALYSIS OF PARAQUAT IN BIOLOGICAL-FLUIDS
    BRAITHWAITE, RA
    [J]. HUMAN TOXICOLOGY, 1987, 6 (01): : 83 - 86
  • [8] COMPARISON OF CAPILLARY ELECTROPHORESIS AND REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF PARAQUAT, DIQUAT AND DIFENZOQUAT
    CARNEIRO, MC
    PUIGNOU, L
    GALCERAN, MT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) : 217 - 224
  • [9] BISQUATERNARY-DRUG MEMBRANE ELECTRODES WITH HIGH-SENSITIVITY
    COSOFRET, VV
    BUCK, RP
    [J]. ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) : 357 - 362
  • [10] FRANKE G, 1979, FRESEN Z ANAL CHEM, V298, P38