Scatter-glare estimation for digital radiographic systems: Comparison of digital filtration and sampling techniques

被引:20
作者
Molloi, S [1 ]
Zhou, YF [1 ]
Wamsely, G [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
关键词
convolution filtering; digital subtraction angiography; scatter; veiling glare;
D O I
10.1109/42.746621
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The scatter and veiling glare distribution in images acquired with a digital subtraction angiography imaging system was estimated using a digital filtration and a beam-stop technique. The digital filtration technique utilizes exposure parameters and image gray levels to estimate scatter-glare intensity based on previous phantom measurements. The beam-stop technique uses an array of lead discs in order to sample scatter-glare intensity for each patient. To test the ability of digital filtration and beam-stop techniques to estimate the scatter-glare intensity, they were applied to images of postmortem swine animal models at different projections and beam energies. The systematic and root-mean-square (rms) percentage errors of these estimates were obtained by comparison to directly measured scatter-glare images using a scanning lead strip technique. The average rms percentage error for the digital filtration and beam-stop techniques were 8.07% and 6.67%, respectively. The changes in scatter-glare intensity due to contrast injection during coronary arteriography and ventriculography were also measured using the beam-stop technique. The maximum changes in scatter-glare intensities during coronary arteriography and ventriculography were 19 and 88%, respectively. The results indicate that the digital filtration technique is more suited for applications such as coronary arteriography and ventriculography where! the iodinated contrast material significantly changes the scatter-glare intensity.
引用
收藏
页码:881 / 888
页数:8
相关论文
共 19 条
[1]  
Barnes G T, 1979, Med Phys, V6, P197, DOI 10.1118/1.594562
[2]   A DIGITAL FILTRATION TECHNIQUE FOR SCATTER-GLARE CORRECTION BASED ON THICKNESS ESTIMATION [J].
ERSAHIN, A ;
MOLLOI, S ;
QIAN, YJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (03) :587-595
[3]   CORONARY BLOOD-FLOW MEASUREMENT USING AN ANGIOGRAPHIC 1ST PASS DISTRIBUTION TECHNIQUE - A FEASIBILITY STUDY [J].
HANGIANDREOU, NJ ;
FOLTS, JD ;
PEPPLER, WW ;
MISTRETTA, CA .
MEDICAL PHYSICS, 1991, 18 (05) :947-954
[4]   A TECHNIQUE OF SCATTER-GLARE CORRECTION USING A DIGITAL FILTRATION [J].
HONDA, M ;
EMA, T ;
KIKUCHI, K ;
OHE, M ;
KOMATSU, K .
MEDICAL PHYSICS, 1993, 20 (01) :59-69
[5]   A REGIONAL CONVOLUTION KERNEL ALGORITHM FOR SCATTER CORRECTION IN DUAL-ENERGY IMAGES - COMPARISON TO SINGLE-KERNEL ALGORITHMS [J].
KRUGER, DG ;
ZINK, F ;
PEPPLER, WW ;
ERGUN, DL ;
MISTRETTA, CA .
MEDICAL PHYSICS, 1994, 21 (02) :175-184
[6]   EFFECTIVENESS OF ANTISCATTER GRIDS IN DIGITAL SUBTRACTION ANGIOGRAPHY [J].
KRUGER, RA ;
SORENSON, JA ;
NIKLASON, LT .
INVESTIGATIVE RADIOLOGY, 1983, 18 (03) :293-297
[7]   SCATTER ESTIMATION FOR A DIGITAL RADIOGRAPHIC SYSTEM USING CONVOLUTION FILTERING [J].
LOVE, LA ;
KRUGER, RA .
MEDICAL PHYSICS, 1987, 14 (02) :178-185
[8]   Quantification of volumetric coronary blood flow with dual-energy digital subtraction angiography [J].
Molloi, S ;
Ersahin, A ;
Tang, J ;
Hicks, J ;
Leung, CY .
CIRCULATION, 1996, 93 (10) :1919-1927
[9]   IN-VIVO VALIDATION OF VIDEODENSITOMETRIC CORONARY CROSS-SECTIONAL AREA MEASUREMENT USING DUAL-ENERGY DIGITAL SUBTRACTION ANGIOGRAPHY [J].
MOLLOI, S ;
ERSAHIN, A ;
HICKS, J ;
WALLIS, J .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1995, 11 (04) :223-231
[10]   CCD camera for dual-energy digital subtraction angiography [J].
Molloi, S ;
Ersahin, A ;
Qian, YJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (04) :747-752