Advantages and disadvantages of nonfusion technology in spine surgery

被引:76
作者
Huang, RC
Girardi, FP
Lim, MR
Cammisa, FP
机构
[1] Hosp Special Surg, New York, NY 10021 USA
[2] Weill Cornell Med Coll, New York, NY USA
[3] Thomas Jefferson Univ, Philadelphia, PA 19107 USA
关键词
D O I
10.1016/j.ocl.2005.02.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Nonfusion technology in spine surgery may improve outcomes by reducing surgical morbidity and the incidence of adjacent level degeneration; however, new technologies also introduce new short- and long-term complications. There is currently no evidence that nonfusion implants are superior to fusion in mid- to long-term follow-up. Understanding the potential risks and benefits of nonfusion technology is essential for spine surgeons and their patients. This article reviews the current evidence relating to the potential risks and benefits of nonfusion technology in spine surgery.
引用
收藏
页码:263 / +
页数:8
相关论文
共 56 条
[1]
Threaded cortical bone dowels for lumbar interbody fusion: over 1-year mean follow up in 28 patients [J].
Barnes, B ;
Rodts, GE ;
McLaughlin, MR ;
Haid, RW .
JOURNAL OF NEUROSURGERY, 2001, 95 (01) :1-4
[2]
Surgical and clinical results with the PDN® prosthetic disc-nucleus device [J].
Bertagnoli, R ;
Schönmayr, R .
EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) :S143-S148
[3]
ABNORMAL MAGNETIC-RESONANCE SCANS OF THE LUMBAR SPINE IN ASYMPTOMATIC SUBJECTS - A PROSPECTIVE INVESTIGATION [J].
BODEN, SD ;
DAVIS, DO ;
DINA, TS ;
PATRONAS, NJ ;
WIESEL, SW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :403-408
[4]
ABNORMAL MAGNETIC-RESONANCE SCANS OF THE CERVICAL-SPINE IN ASYMPTOMATIC SUBJECTS - A PROSPECTIVE INVESTIGATION [J].
BODEN, SD ;
MCCOWIN, PR ;
DAVIS, DO ;
DINA, TS ;
MARK, AS ;
WIESEL, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (08) :1178-1184
[5]
ROBINSON ANTERIOR CERVICAL DISKECTOMY AND ARTHRODESIS FOR CERVICAL RADICULOPATHY - LONG-TERM FOLLOW-UP OF 100 AND 22 PATIENTS [J].
BOHLMAN, HH ;
EMERY, SE ;
GOODFELLOW, DB ;
JONES, PK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (09) :1298-1307
[6]
Three- and four-level anterior cervical discectomy and fusion with plate fixation - A prospective study [J].
Bolesta, MJ ;
Rechtine, GR ;
Chrin, AM .
SPINE, 2000, 25 (16) :2040-2044
[7]
Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients [J].
Chou, WY ;
Hsu, CJ ;
Chang, WN ;
Wong, CY .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (01) :39-43
[8]
Circumferential lumbar spinal fusion with Brantigan cage versus posterolateral fusion with titanium Cotrel-Dubousset instrumentation -: A prospective, randomized clinical study of 146 patients [J].
Christensen, FB ;
Hansen, ES ;
Eiskjær, SP ;
Hoy, K ;
Helmig, P ;
Neumann, P ;
Niedermann, B ;
Bünger, CE .
SPINE, 2002, 27 (23) :2674-2683
[9]
Results of disc prosthesis after a minimum follow-up period of 2 years [J].
Cinotti, G ;
David, T ;
Postacchini, F .
SPINE, 1996, 21 (08) :995-1000
[10]
ProDisc artificial total lumbar disc replacement: Introduction and early results from the United States clinical trial [J].
Delamarter, RB ;
Fribourg, DM ;
Kanim, LFA ;
Bae, H .
SPINE, 2003, 28 (20) :S167-S175