Circumferential lumbar spinal fusion with Brantigan cage versus posterolateral fusion with titanium Cotrel-Dubousset instrumentation -: A prospective, randomized clinical study of 146 patients

被引:144
作者
Christensen, FB [1 ]
Hansen, ES [1 ]
Eiskjær, SP [1 ]
Hoy, K [1 ]
Helmig, P [1 ]
Neumann, P [1 ]
Niedermann, B [1 ]
Bünger, CE [1 ]
机构
[1] Aarhus Univ Hosp, Orthoped Res Lab, Dept Orthoped Surg, Spine Sect, DK-8000 Aarhus C, Denmark
关键词
circumferential fusion; functional outcome; lumbar spinal fusion; prospective randomized clinical study;
D O I
10.1097/00007632-200212010-00006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A prospective randomized clinical study with a 2-year follow-up period was conducted. Objective. To analyze the effects of circumferential fusion using ALIF radiolucent carbon fiber cages and titanium posterior instrumentation on functional outcome, fusion rate, complications, and lumbar lordosis. Summary of Background Data. Circumferential fusion has become a common procedure in lumbar spine fusion, both as a primary and salvage procedure. However, the claimed advantages of ALIF plus PLF over conventional PLF lack scientific documentaion. Methods. From April 1996 through November 1999 a total of 148 patients with severe chronic low back pain were randomly selected for either posterolateral lumbar fusion with titanium CD-Horizon (posterolateral group) or circumferential fusion with a ALIF Brantigan cage plus posterior instrumentation. The Dallas Pain Questionnaire (DPQ), the Low Back Pain Rating Scale (LBPR), and a questionnaire concerning work status assessed their outcomes. Results. Both groups showed highly significant improvement in all four categories of life quality (DPQ) as well as in the back pain and leg pain index (LBPR), as compared with preoperative status. There was a clear tendency toward better overall functional outcome for patients with the circumferential procedure (P < 0.08), and this patient group also showed significantly less leg pain at the 1-year follow-up evaluation (P < 0.03) and less peak back pain at 2 years (P < 0.04). Sagittal lordosis was restored and maintained in the circumferential group (P < 0.01). The circumferential fusion patients showed a higher posterolateral fusion rate (92%) than the posterolateral group (80%) (P < 0.04). the repeat operation rate including implant removal was significantly lower in the circumferential group (7%) (P < 0.009) than in the posterolateral group (22%). Conclusions. Circumferential lumbar fusion restored lordosis, provided a higher union rate with significantly fewer repeat operations, showed a tendency toward better functional outcome, and resulted in less peak back pain and leg pain than instrumented posterolateral fusion. The clinical perspective of the current study implies a recommendation to favor circumferential fusion as a definitive surgical procedure in complex lumbar pathology involving major instability, flatback, and previous disc surgery in younger patients, as compared with posterolateral fusion with pedicle screws alone.
引用
收藏
页码:2674 / 2683
页数:10
相关论文
共 49 条
  • [1] Management of symptomatic lumbar pseudarthrosis with anteroposterior fusion - A functional and radiographic outcome study
    Albert, TJ
    Pinto, M
    Denis, F
    [J]. SPINE, 2000, 25 (01) : 123 - 129
  • [2] Anterior lumbar fusion improves discogenic pain at levels of prior posterolateral fusion
    Barrick, WT
    Schofferman, JA
    Reynolds, JB
    Goldthwaite, ND
    McKeehen, M
    Keaney, D
    White, AH
    [J]. SPINE, 2000, 25 (07) : 853 - 857
  • [3] Can it be predicted which patients with chronic low back pain should be offered tertiary rehabilitation in a functional restoration program?: A search for demographic, socioeconomic, and physical predictors
    Bendix, AF
    Bendix, T
    Hæstrup, C
    [J]. SPINE, 1998, 23 (16) : 1775 - 1783
  • [4] INTERBODY LUMBAR FUSION USING A CARBON-FIBER CAGE IMPLANT VERSUS ALLOGRAFT BONE - AN INVESTIGATIONAL STUDY IN THE SPANISH GOAT
    BRANTIGAN, JW
    MCAFEE, PC
    CUNNINGHAM, BW
    WANG, H
    ORBEGOSO, CM
    [J]. SPINE, 1994, 19 (13) : 1436 - 1444
  • [5] A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS
    BRANTIGAN, JW
    STEFFEE, AD
    [J]. SPINE, 1993, 18 (14) : 2106 - 2117
  • [6] Lumbar interbody fusion using the Brantigan I/F Cage for posterior lumbar interbody fusion and the variable pedicle screw placement system - Two-year results from a Food and Drug Administration Investigational Device Exemption Clinical Trial
    Brantigan, JW
    Steffee, AD
    Lewis, ML
    Quinn, LM
    Persenaire, JM
    [J]. SPINE, 2000, 25 (11) : 1437 - 1446
  • [7] SPINAL PAIN REHABILITATION - INPATIENT AND OUTPATIENT TREATMENT RESULTS AND DEVELOPMENT OF PREDICTORS FOR OUTCOME
    CAIRNS, D
    MOONEY, V
    CRANE, P
    [J]. SPINE, 1984, 9 (01) : 91 - 95
  • [8] Christensen F B, 1996, Eur Spine J, V5, P293, DOI 10.1007/BF00304343
  • [9] Interobserver and intraobserver agreement of radiograph interpretation with and without pedicle screw implants -: The need for a detailed classification system in posterolateral spinal fusion
    Christensen, FB
    Laursen, M
    Gelineck, J
    Eiskjær, SP
    Thomsen, K
    Bunger, CE
    [J]. SPINE, 2001, 26 (05) : 538 - 543
  • [10] Long-term functional outcome of pedicle screw instrumentation as a support for posterolateral spinal fusion -: Randomized clinical study with a 5-year follow-up
    Christensen, FB
    Hansen, ES
    Laursen, M
    Thomsen, K
    Bünger, CE
    [J]. SPINE, 2002, 27 (12) : 1269 - 1277