Accurate recording and measurement of electron diffraction data in structural and difference Fourier studies of proteins

被引:7
作者
Downing, KH [1 ]
Li, HL [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Div Life Sci, Donner Lab, Berkeley, CA 94720 USA
关键词
protein structure; electron crystallography; electron diffraction; difference Fourier; tubulin; ligand binding;
D O I
10.1017/S1431927601010406
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Many of the techniques that have been developed in X-ray crystallography are being applied in electron crystallographic studies of proteins. Electron crystallography has the advantage of measuring structure factor phases directly from high resolution images with an accuracy substantially higher than is common in X-ray crystallography. However, electron diffraction amplitudes are often not as precise as those obtained in X-ray work. We discuss here some approaches to maximizing the reliability of the diffraction amplitudes through choice of exposure and data processing schemes. With accurate measurement of diffraction data, Fourier difference methods can be used in electron crystallographic studies of small, localized changes of proteins that exist in two-dimensional crystals. The mathematical basis for the power of these methods in detecting small changes is reviewed. We then discuss several issues related to optimizing the quality of the diffraction data and derive an expression for the best exposure for recording diffraction patterns. An application of Fourier difference maps in localizing drug binding sites on the protein tubulin is discussed.
引用
收藏
页码:407 / 417
页数:11
相关论文
共 23 条
[1]  
BALDWIN J, 1984, ULTRAMICROSCOPY, V14, P319, DOI 10.1016/0304-3991(84)90217-1
[2]  
BOLLAG DM, 1995, CANCER RES, V55, P2325
[3]   APPLICATIONS OF A SLOW-SCAN CCD CAMERA IN PROTEIN ELECTRON CRYSTALLOGRAPHY [J].
BRINK, J ;
CHIU, W .
JOURNAL OF STRUCTURAL BIOLOGY, 1994, 113 (01) :23-34
[4]   The projection structure of the low temperature K intermediate of the bacteriorhodopsin photocycle determined by electron diffraction [J].
Bulllough, PA ;
Henderson, R .
JOURNAL OF MOLECULAR BIOLOGY, 1999, 286 (05) :1663-1671
[5]   Performance of a 2k CCD camera designed for electron crystallography at 400 kV [J].
Downing, KH ;
Hendrickson, FM .
ULTRAMICROSCOPY, 1999, 75 (04) :215-233
[6]  
DRENTH J, 1994, PRINCIPLES PROTEIN X
[7]   Cooled CCD detector with tapered fibre optics for recording electron diffraction patterns [J].
Faruqi, AR ;
Henderson, R ;
Subramaniam, S .
ULTRAMICROSCOPY, 1999, 75 (04) :235-250
[8]   HIGH-RESOLUTION ELECTRON CRYSTALLOGRAPHY OF PROTEIN MOLECULES [J].
GLAESER, RM ;
DOWNING, KH .
ULTRAMICROSCOPY, 1993, 52 (3-4) :478-486
[9]   Diffuse scattering in electron diffraction data from protein crystals [J].
Grigorieff, N ;
Henderson, R .
ULTRAMICROSCOPY, 1995, 60 (02) :295-309
[10]   RADIATION-DAMAGE OF PURPLE MEMBRANE AT LOW-TEMPERATURE [J].
HAYWARD, SB ;
GLAESER, RM .