Comparative evaluation of software for deconvolution of metabolomics data based on GC-TOF-MS

被引:114
作者
Lu, Hongmei [1 ]
Dunn, Warwick B. [2 ,3 ]
Shen, Hailin [2 ,3 ]
Kell, Douglas B. [2 ,3 ]
Liang, Yizeng [1 ]
机构
[1] Cent S Univ, Coll Chem & Chem Engn, Changsha 410083, Peoples R China
[2] Univ Manchester, Manchaster Ctr Integrat Syst Biol, Manchester Interdisciplinary Bioctr, Manchester M1 7DN, Lancs, England
[3] Univ Manchester, Bioanalyt Sci Grp, Manchester Interdisciplinary Bioctr, Manchester M1 7DN, Lancs, England
基金
英国生物技术与生命科学研究理事会; 英国医学研究理事会;
关键词
component search; gas chromatography-mass spectrometry; GC-MS; metabolomics; software; spectral deconvolution;
D O I
10.1016/j.trac.2007.11.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditional options available for deconvolution of data from gas chromatography-mass spectrometry (GC-MS) experiments have mostly been confined to semi-automated methods, which cannot compete with high-throughput and rapid analysis in metabolomics. In the present study, data sets acquired using GC with time-of-flight MS (GC-TOF-MS) were processed using three different deconvolution software packages (LECO ChromaTOF, AMDIS and SpectralWorks AnalyzerPro). We paid attention to the extent of detection, identification and agreement of qualitative results, and took interest in the flexibility and the productivity of these programs in their application. We made comparisons using data from the analysis of a test-mixture solution of 36 endogenous metabolites with a wide range of relative concentration ratios. We detected differences in the number of components identified and the accuracy of deconvolution. Using the AMDIS Search program, the resulting mass spectra after deconvolution were searched against the author-constructed retention index/mass spectral libraries containing both the mass spectra and the retention indices of derivatives of a set of metabolites. We based analyte identifications on both retention indices and spectral similarity. The results showed that there were large differences in the numbers of components identified and the qualitative results from the three programs. AMDIS and ChromaTOF produced a large number of false positives, while AnalyzerPro produced some false negatives. We found that, in these three software packages, component width is the most important parameter for predicting the accuracy of the deconvoluted result. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:215 / 227
页数:13
相关论文
共 29 条
[21]   Gas chromatography mass spectrometry-based metabolite profiling in plants [J].
Lisec, Jan ;
Schauer, Nicolas ;
Kopka, Joachim ;
Willmitzer, Lothar ;
Fernie, Alisdair R. .
NATURE PROTOCOLS, 2006, 1 (01) :387-396
[22]  
Malinowski ER, 1996, J CHEMOMETR, V10, P273, DOI 10.1002/(SICI)1099-128X(199607)10:4<273::AID-CEM418>3.0.CO
[23]  
2-5
[24]   Resolution of two-way data from hyphenated chromatography by means of elementary matrix transformations [J].
Manne, R ;
Grande, BV .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) :35-46
[25]   Metabolomics and the challenges ahead [J].
Mendes, Pedro .
BRIEFINGS IN BIOINFORMATICS, 2006, 7 (02) :127-127
[26]   Closed-loop, multiobjective optimization of analytical instrumentation: Gas chromatography/time-of-flight mass spectrometry of the metabolomes of human serum and of yeast fermentations [J].
O'Hagan, S ;
Dunn, WB ;
Brown, M ;
Knowles, JD ;
Kell, DB .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :290-303
[27]   Simultaneous analysis of metabolites in potato tuber by gas chromatography-mass spectrometry [J].
Roessner, U ;
Wagner, C ;
Kopka, J ;
Trethewey, RN ;
Willmitzer, L .
PLANT JOURNAL, 2000, 23 (01) :131-142
[28]   Centering, scaling, and transformations: improving the biological information content of metabolomics data [J].
van den Berg, Robert A. ;
Hoefsloot, Huub C. J. ;
Westerhuis, Johan A. ;
Smilde, Age K. ;
van der Werf, Mariet J. .
BMC GENOMICS, 2006, 7 (1)
[29]  
Villas-Boas S.G., 2007, Metabolome Analysis: An Introduction