Prediction of Low-Voltage Tetrafluoromethane Emissions Based on the Operating Conditions of an Aluminium Electrolysis Cell

被引:11
作者
Dion, Lukas [1 ]
Kiss, Laszlo I. [1 ]
Poncsak, Sandor [1 ]
Lagace, Charles-Luc [2 ]
机构
[1] Univ Quebec Chicoutimi, 555 Blvd Univ, Chicoutimi, PQ G7H 2B1, Canada
[2] Aluminerie Alouette Inc, 400 Chemin Pointe Noire, Sept Iles, PQ G4R 5M9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Aluminium electrolysis cells - Greenhouse gas (GHG) - Individual anode currents - Operating condition - Predictive algorithms - Qualitative information - Standard deviation - Tetrafluoromethane;
D O I
10.1007/s11837-016-2043-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Greenhouse gas (GHG) generation is inherent in the production of aluminium by a technology that uses carbon anodes. Most of those GHG are composed of CO2 produced by redox reaction that occurs in the cell. However, a significant fraction of the annual GHG production is composed of perfluorocarbons (PFC) resulting from anode effects (AE). Multiple investigations have shown that tetrafluoromethane (CF4) can be generated under low-voltage conditions in the electrolysis cells, without global anode effect. The aim of this paper is to find a quantitative relationship between monitored cell parameters and the emissions of CF4. To achieve this goal, a predictive algorithm has been developed using seven cell indicators. These indicators are based on the cell voltage, the noise level and other parameters calculated from individual anode current monitoring. The predictive algorithm is structured into three different steps. The first two steps give qualitative information while the third one quantitatively describes the expected CF4 concentration at the duct end of the electrolysis cells. Validations after each step are presented and discussed. Finally, a sensitivity analysis was performed to understand the effect of each indicator on the onset of low-voltage PFC emissions. The standard deviation of individual anode currents was found to be the dominant variable. Cell voltage, noise level, and maximum individual anode current also showed a significant correlation with the presence of CF4 in the output gas of an electrolysis cell.
引用
收藏
页码:2472 / 2482
页数:11
相关论文
共 22 条
[21]   PFC Emissions from Detected Versus Nondetected Anode Effects in the Aluminum Industry [J].
Wong, David S. ;
Fraser, Paul ;
Lavoie, Pascal ;
Kim, Jooil .
JOM, 2015, 67 (02) :342-353
[22]  
Zarouni A.A., 2013, Light Metals 2013, P859, DOI [10.1007/978-3-319-65136-1146, DOI 10.1007/978-3-319-65136-1_146]