From medical images to anatomically accurate finite element grids

被引:108
作者
Cebral, JR [1 ]
Löhner, R [1 ]
机构
[1] George Mason Univ, Sch Computat Sci, Fairfax, VA 22030 USA
关键词
grid generation; hemodynamics; medical images; finite element modelling;
D O I
10.1002/nme.205
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The successful application of computational modelling of blood flow for the planning of surgical and interventional procedures to treat cardiovascular diseases strongly depends on the rapid construction of anatomical models. The large individual variability of the human vasculature and the strong dependence of blood flow characteristics on the vessel geometry require modelling on a patient-specific basis. Various image processing and geometrical modelling techniques are integrated for the rapid construction of geometrical surface models of arteries starting from medical images. These discretely defined surfaces are then used to generate anatomically accurate finite element grids for hemodynamic simulations. The proposed methodology operates directly in 3D and consists of three stages. In the first stage, the images are filtered to reduce noise and segmented using a region-growing algorithm in order to obtain a properly defined boundary of the arterial lumen walls. In the second stage, a surface triangulation representing the vessel walls is generated using a direct tessellation of the boundary voxels. This surface is then smoothed and the quality of the resulting triangulation is improved. Finally, in the third stage, the triangulation is subdivided into so-called discrete surface patches for surface gridding, the desired element size distribution is defined and the finite element grid generated. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:985 / 1008
页数:24
相关论文
共 38 条
[21]  
Lohner R, 1996, COMMUN NUMER METH EN, V12, P683, DOI 10.1002/(SICI)1099-0887(199610)12:10<683::AID-CNM983>3.0.CO
[22]  
2-1
[23]   An unstructured grid-based, parallel free surface solver [J].
Löhner, R ;
Yang, C ;
Oñate, E ;
Idelssohn, S .
APPLIED NUMERICAL MATHEMATICS, 1999, 31 (03) :271-293
[24]   Convective mass transfer at the carotid bifurcation [J].
Ma, PP ;
Li, XM ;
Ku, DN .
JOURNAL OF BIOMECHANICS, 1997, 30 (06) :565-571
[25]  
Mazumdar JN, 1992, BIOFLUID MECH
[26]  
MCINERNEY T, 1997, P CVR MED 97 GREN FR
[27]   Accuracy of computational hemodynamics in complex arterial geometries reconstructed from magnetic resonance imaging [J].
Moore, JA ;
Steinman, DA ;
Holdsworth, DW ;
Ethier, CR .
ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (01) :32-41
[28]  
Moore JA, 1998, J BIOMECH, V31, P179, DOI 10.1016/S0021-9290(97)00125-5
[29]  
Perktold K, 1995, WORLD CONGR BIOMECH, P83
[30]   PULSATILE NON-NEWTONIAN BLOOD-FLOW IN 3-DIMENSIONAL CAROTID BIFURCATION MODELS - A NUMERICAL STUDY OF FLOW PHENOMENA UNDER DIFFERENT BIFURCATION ANGLES [J].
PERKTOLD, K ;
PETER, RO ;
RESCH, M ;
LANGS, G .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (06) :507-515