Preliminary evaluation of a lateral flow immunoassay device for screening urine samples for the presence of sulphamethazine

被引:44
作者
O'Keeffe, M [1 ]
Crabbe, P
Salden, M
Wichers, J
Van Peteghem, C
Kohen, F
Pieraccini, G
Moneti, G
机构
[1] TEAGASC, Natl Food Ctr, Dublin 15, Ireland
[2] State Univ Ghent, Fac Pharmaceut Sci, Lab Food Anal, B-9000 Ghent, Belgium
[3] EuroDiagnost BV, Arnhem, Netherlands
[4] ATO, Agrotechnol Res Inst, NL-6708 PD Wageningen, Netherlands
[5] Weizmann Inst Sci, Dept Regulat Biol, IL-76100 Rehovot, Israel
[6] Univ Florence, Ctr Interdipartimentale Serv Spettrometria Massa, I-50134 Florence, Italy
关键词
lateral flow immunoassay; sulphamethazine; residue analysis; urine samples; monoclonal antibody; test kit;
D O I
10.1016/S0022-1759(03)00207-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A lateral flow immunoassay (LFIA) device was developed and applied to testing urine samples for residues of the antimicrobial sulphamethazine (SMZ). This report describes the preparation of a rat monoclonal antibody to SMZ and its characterisation in an ELISA format. Apart from SMZ, the antibody showed high (greater than or equal to50%) cross-reactivity to N-4-acetyl-sulphamethazine (55%), sulphamerazine (59%) and sulphisoxazole (50%) and lower cross-reactivity of 18% to sulphachlorpyridazine and sulphadiazine. The LFIA device consisted of a nitrocellulose membrane spotted with SMZ-ovalbumin and goat anti-mouse antibody as capture line and control line, respectively. Mouse anti-rat IgG F(ab)2 fragment specific antibody, adsorbed to colloidal carbon, was used as the detection ligand in the LFIA. The LFIA device had a cut-off value of 6.3 ng/ml in diluted (1/10) urine. Urine samples from SMZ-treated pigs, and bovine and porcine urine samples fortified with SMZ were used for a blind, four-laboratory evaluation of the performance of the LFIA device. Concentrations of SMZ in the test samples (n=29), as determined by LC-MS/MS, ranged from 0 (<3) to 1174 ng/ml. The evaluation of the LFIA device showed an overall sensitivity of 100%, a specificity of 71%, and positive and negative prediction values of 73% and 100%, respectively. The LFIA device has been fabricated as a test kit for detennining SMZ residues in animals produced for slaughter. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 12 条
[11]   DETERMINATION OF SULFAMETHAZINE IN ANIMAL-TISSUES BY ENZYME-IMMUNOASSAY [J].
RENSON, C ;
DEGAND, G ;
MAGHUINROGISTER, G ;
DELAHAUT, P .
ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) :323-328
[12]   COLLOIDAL CARBON PARTICLES AS A NEW LABEL FOR RAPID IMMUNOCHEMICAL TEST METHODS - QUANTITATIVE COMPUTER IMAGE-ANALYSIS OF RESULTS [J].
VANAMERONGEN, A ;
WICHERS, JH ;
BERENDSEN, LBJM ;
TIMMERMANS, AJM ;
KEIZER, GD ;
VANDOORN, AWJ ;
BANTJES, A ;
VANGELDER, WMJ .
JOURNAL OF BIOTECHNOLOGY, 1993, 30 (02) :185-195