Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans

被引:134
作者
Cleveland, Zackary I. [1 ,2 ]
Cofer, Gary P. [1 ,2 ]
Metz, Gregory [3 ]
Beaver, Denise [3 ]
Nouls, John [1 ,2 ]
Kaushik, S. Sivaram [1 ,2 ]
Kraft, Monica [3 ]
Wolber, Jan
Kelly, Kevin T. [4 ]
McAdams, H. Page [2 ]
Driehuys, Bastiaan [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[3] Duke Univ, Med Ctr, Dept Med, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC USA
来源
PLOS ONE | 2010年 / 5卷 / 08期
基金
美国国家卫生研究院;
关键词
LASER-POLARIZED XE-129; NUCLEAR-MAGNETIC-RESONANCE; REGIONAL LUNG DENSITY; SINGLE BREATH-HOLD; DIFFUSING-CAPACITY; BLOOD-FLOW; HE-3; MRI; MORPHOMETRIC TECHNIQUES; PULMONARY PERFUSION; NOBLE-GASES;
D O I
10.1371/journal.pone.0012192
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange. Methods and Principal Findings: Here we exploit the solubility, high magnetic resonance (MR) signal intensity, and large chemical shift of hyperpolarized (HP) Xe-129 to probe the regional uptake of alveolar gases by directly imaging HP Xe-129 dissolved in the gas exchange tissues and pulmonary capillary blood of human subjects. The resulting single breath-hold, three-dimensional MR images are optimized using millisecond repetition times and high flip angle radio-frequency pulses, because the dissolved HP Xe-129 magnetization is rapidly replenished by diffusive exchange with alveolar Xe-129. The dissolved HP Xe-129 MR images display significant, directional heterogeneity, with increased signal intensity observed from the gravity-dependent portions of the lungs. Conclusions: The features observed in dissolved-phase Xe-129 MR images are consistent with gravity-dependent lung deformation, which produces increased ventilation, reduced alveolar size (i.e., higher surface-to-volume ratios), higher tissue densities, and increased perfusion in the dependent portions of the lungs. Thus, these results suggest that dissolved HP Xe-129 imaging reports on pulmonary function at a fundamental level.
引用
收藏
页数:8
相关论文
共 62 条
[1]   Measurement of xenon diffusing capacity in the rat lung by hyperpolarized 129Xe MRI and dynamic spectroscopy in a single breath-hold [J].
Abdeen, Nishard ;
Cross, Albert ;
Cron, Gregory ;
White, Steven ;
Rand, Thomas ;
Miller, David ;
Santyr, Giles .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :255-264
[2]   Blood flow switching among pulmonary capillaries is decreased during high hematocrit [J].
Baumgartner, WA ;
Peterson, AJ ;
Presson, RG ;
Tanabe, N ;
Jaryszak, EM ;
Wagner, WW .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (02) :522-526
[3]   REGIONAL LUNG DENSITY AND BLOOD-VOLUME IN NONSMOKING AND SMOKING SUBJECTS MEASURED BY PET [J].
BRUDIN, LH ;
RHODES, CG ;
VALIND, SO ;
WOLLMER, P ;
HUGHES, JMB .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (04) :1324-1334
[4]   REGIONAL LUNG HEMATOCRIT IN HUMANS USING POSITRON EMISSION TOMOGRAPHY [J].
BRUDIN, LH ;
VALIND, SO ;
RHODES, CG ;
TURTON, DR ;
HUGHES, JMB .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (04) :1155-1163
[5]   Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent [J].
Bucholz, Elizabeth ;
Ghaghada, Ketan ;
Qi, Yi ;
Mukundan, Srinivasan ;
Johnson, G. Allan .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) :111-118
[6]   TISSUE-BLOOD PARTITION-COEFFICIENT FOR XENON - TEMPERATURE AND HEMATOCRIT DEPENDENCE [J].
CHEN, RYZ ;
FAN, FC ;
KIM, S ;
JAN, KM ;
USAMI, S ;
CHIEN, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1980, 49 (02) :178-183
[7]   Estimated functional diameter of alveolar septal microvessels in zone 1 [J].
Conhaim, RL ;
Rodenkirch, LA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 271 (03) :H996-H1003
[8]   COMPARISON OF TOTAL LUNG DIFFUSION CAPACITY AND THE MEMBRANE COMPONENT OF DIFFUSION CAPACITY AS DETERMINED BY PHYSIOLOGIC AND MORPHOMETRIC TECHNIQUES [J].
CRAPO, JD ;
CRAPO, RO .
RESPIRATION PHYSIOLOGY, 1983, 51 (02) :183-194
[9]   EVALUATION OF LUNG DIFFUSING-CAPACITY BY PHYSIOLOGICAL AND MORPHOMETRIC TECHNIQUES [J].
CRAPO, JD ;
CRAPO, RO ;
JENSEN, RL ;
MERCER, RR ;
WEIBEL, ER .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (05) :2083-2091
[10]   Evaluation of asthma with hyperpolarized helium-3 MRI - Correlation with clinical severity and spirometry [J].
de lange, Eduard E. ;
Altes, Talissa A. ;
Patrie, James T. ;
Gaare, John D. ;
Knake, Jeffrey J. ;
Mugler, John P., III ;
Platts-Mills, Thomas A. .
CHEST, 2006, 130 (04) :1055-1062