A reagentless amperometric hydrogen peroxide biosensor based on covalently binding horseradish peroxidase and thionine using a thiol-modified gold electrode

被引:51
作者
Ruan, CM [1 ]
Yang, R [1 ]
Chen, XH [1 ]
Deng, JQ [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
self-assembled monolayer; horseradish peroxidase; thionine; hydrogen peroxide;
D O I
10.1016/S0022-0728(98)00153-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach to construct a reagentless hydrogen peroxide biosensor is described. Horseradish peroxidase and thionine are covalently bound to a cysteamine-assembled gold electrode using glutaraldehyde as a bifunctional reagent. Thionine immobilised in this way can shuttle electrons between the electrode and the redox activity center of the enzyme. The sensor was highly sensitive to hydrogen peroxide with a detection limit of 8.0 x 10(-7) mol l(-1) and a response time of less than 4 s. The effects of the applied potential and the pH values of the buffer solution on the response of the sensor were investigated for optimum analytical performance. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 30 条
[1]   Electrocatalytic oxidation of NADH at a gold electrode modified by thionine covalently bound to self-assembled cysteamine monolayers [J].
Chen, HY ;
Zhou, DM ;
Xu, JJ ;
Fang, HQ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 422 (1-2) :21-25
[2]   CONSEQUENCES OF MICROSCOPIC SURFACE-ROUGHNESS FOR MOLECULAR SELF-ASSEMBLY [J].
CREAGER, SE ;
HOCKETT, LA ;
ROWE, GK .
LANGMUIR, 1992, 8 (03) :854-861
[3]   SELF-ASSEMBLED MONOLAYERS AND ENZYME ELECTRODES - PROGRESS, PROBLEMS AND PROSPECTS [J].
CREAGER, SE ;
OLSEN, KG .
ANALYTICA CHIMICA ACTA, 1995, 307 (2-3) :277-289
[4]  
DANIEL M, 1996, ELECTROANAL, V8, P207
[5]   OXIDATION OF PHENOL AND ITS REACTION-PRODUCT BY HORSERADISH-PEROXIDASE AND HYDROGEN-PEROXIDE [J].
DANNER, DJ ;
BRIGNAC, PJ ;
ARCENEAU.D ;
PATEL, V .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1973, 156 (02) :759-763
[6]   SEPARATION-FREE SANDWICH ENZYME IMMUNOASSAYS USING MICROPOROUS GOLD ELECTRODES AND SELF-ASSEMBLED MONOLAYER IMMOBILIZED CAPTURE ANTIBODIES [J].
DUAN, CM ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1369-1377
[7]   Voltammetric responsive sensors for organic compounds based on organized self-assembled lipoyl-beta-cyclodextrin derivative monolayer on a gold electrode [J].
He, PA ;
Ye, JN ;
Fang, YH ;
Suzuki, I ;
Osa, T .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :217-223
[8]   ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY [J].
HURDIS, EC ;
ROMEYN, H .
ANALYTICAL CHEMISTRY, 1954, 26 (02) :320-325
[9]   Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors [J].
Jung, SK ;
Wilson, GS .
ANALYTICAL CHEMISTRY, 1996, 68 (04) :591-596
[10]   GLUCOSE SENSITIVITY OF THIOL MODIFIED GOLD ELECTRODES HAVING IMMOBILIZED GLUCOSE-OXIDASE AND 2-AMINOETHYLFERROCENE [J].
KAJIYA, Y ;
OKAMOTO, T ;
YONEYAMA, H .
CHEMISTRY LETTERS, 1993, (12) :2107-2110