Detection of phenolic compounds in flow systems based on tyrosinase-modified reticulated vitreous carbon electrodes

被引:39
作者
Peña, N [1 ]
Reviejo, AJ [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Dept Analyt Chem, Fac Chem, E-28040 Madrid, Spain
关键词
reticulated vitreous carbon; tyrosinase; flow-through; phenolic compounds;
D O I
10.1016/S0039-9140(01)00414-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and performance of a reticulated vitreous carbon (RVC)-based tyrosinase flow-through electrode, in which the enzyme was covalently immobilized, is reported. The bioelectrode was tested as an amperometric detector for phenolic compounds. Variables affecting the construction of the enzyme flow-through electrode such as the RVC chemical pretreatment procedure, the enzyme immobilization method in the RVC matrix, the enzyme loading and the pH value of the buffer solution used, were optimized by flow-injection with amperometric detection. A good immobilization of the enzyme in the RVC matrix, in spite of the hydrodynamic conditions, was found. The same tyrosinase-RVC electrode could be used with no significant loss of the amperometric response for around 20 days, and reproducible responses could be achieved with different electrodes constructed in the same manner. Moreover, the operational stability of the bioelectrode was tested under continuous monitorization conditions. Calibration plots by flow injection with amperometric detection at -0.20 V were obtained for phenol, 2,4-dimethylphenol; 3-chlorophenol; 4-chlorophenol; 4-chloro-3-methylphenol and 2-aminophenol, with detection limits ranging from 2 mug l(-1) (4-chloro-3-methylphenol) to 2 mg l(-1). (C) 2001 Elsevier Science BN. All rights reserved.
引用
收藏
页码:179 / 187
页数:9
相关论文
共 26 条
[1]   ROTATED POROUS CARBON DISK ELECTRODE [J].
BLAEDEL, WJ ;
WANG, J .
ANALYTICAL CHEMISTRY, 1980, 52 (01) :76-80
[2]   ELECTROCHEMICAL DETECTOR BASED ON A RETICULATED VITREOUS CARBON WORKING ELECTRODE FOR LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
CURRAN, DJ ;
TOUGAS, TP .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :672-678
[3]   Electrochemical behavior of lead deposited on reticulated vitreous carbon [J].
Czerwinski, A ;
Zelazowska, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (01) :55-60
[4]   Supported liquid membrane coupled on-line to potentiometric stripping analysis at a mercury-coated reticulated vitreous carbon electrode for trace metal determinations in urine [J].
Djane, NK ;
Armalis, S ;
Ndung'u, K ;
Johansson, G ;
Mathiasson, L .
ANALYST, 1998, 123 (02) :393-396
[5]  
Ducey MW, 1998, ELECTROANAL, V10, P157, DOI 10.1002/(SICI)1521-4109(199803)10:3<157::AID-ELAN157>3.0.CO
[6]  
2-O
[7]   Electrochemical behavior of porous carbons [J].
Frysz, CA ;
Shui, XP ;
Chung, DDL .
CARBON, 1997, 35 (07) :893-916
[8]   Flow-injection determination of trace hydrogen peroxide or glucose utilizing an amperometric biosensor based on glucose oxidase bound to a reticulated vitreous carbon electrode [J].
Khayyami, M ;
Johansson, G ;
Kriz, D ;
Xie, B ;
Larsson, PO ;
Danielsson, B .
TALANTA, 1996, 43 (06) :957-962
[9]   An amperometric lactate sensor based on a NAD(+)-analog and lactate dehydrogenase coimmobilized on reticulated vitreous carbon [J].
Khayyami, M ;
Garcia, NP ;
Larsson, PO ;
Danielsson, B ;
Johansson, G .
ELECTROANALYSIS, 1997, 9 (07) :523-526
[10]   Development of an amperometric biosensor based on acetylcholine esterase covalently bound to a new support material [J].
Khayyami, M ;
Pita, MTP ;
Garcia, NP ;
Johansson, G ;
Danielsson, B ;
Larsson, PO .
TALANTA, 1998, 45 (03) :557-563