PVC membrane ion selective electrode for the determination of pentachlorophenol in water, wood and soil using tetrazolium pentachlorophenolate

被引:36
作者
Abbas, MN [1 ]
Mostafa, GAE [1 ]
Homoda, AMA [1 ]
机构
[1] Natl Res Ctr, Dept Appl Organ Chem, Microanalyt Lab, Cairo, Egypt
关键词
PVC membrane electrode; pentachlorophenol; triphenyl tetrazolium;
D O I
10.1016/S0039-9140(01)00475-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel PVC membrane electrode selective for the determination of pentachlorophenolate (PCP) ion based on 2,3,5-triphenyl-2H-tetrazolium (TPT) pentachlorophenolate ion pair as an electroactive material is described. The electrode shows a linear response for PCP ion over the concentration range of 6 x 10(-5) to I X 10(-2) M with lower detection limit of 4 x 10(-5) M at 25 degreesC. The electrode posses a Nernstian slope of -55.0 +/- 1.0 mV/decade and a fast potential response of 45 s, which is almost constant over a pH range of 5.5-10.5. Selectivity coefficient data for some common ions show negligible interference, however, 2,4,6-trichlorophenolate and cetylpyridinium ions interfere. An average recovery of 96.2% with relative standard deviation of 2.3% has been achieved for the determination of 75.0 ppm PCP in wastewater samples. The determination of PCP in soil and wood samples gave results that compare favorably with those obtained by gas chromatography. The electrode has been utilized as an end point indicator electrode for the determination of PCP using potentiometric titration. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:647 / 656
页数:10
相关论文
共 36 条
[1]   Cetylpyridinium-iodomercurate PVC membrane ion selective electrode for the determination of cetylpyridinium cation in Ezafluor mouth wash and as a detector for some potentiometric titrations [J].
Abbas, MN ;
Mostafa, GAE ;
Homoda, AMA .
TALANTA, 2000, 53 (02) :425-432
[2]  
Agrawal O, 1998, J AOAC INT, V81, P803
[3]  
ANDRES MD, 1990, J CHROMATOGR, V507, P339
[4]  
BARRIO MAR, 1992, FRESEN J ANAL CHEM, V344, P34
[5]   A SENSITIVE GAS CHROMATOGRAPHIC METHOD FOR DETERMINATION OF PENTACHLOROPHENOL IN HUMAN BLOOD [J].
BEVENUE, A ;
EMERSON, ML ;
CASARETT, LJ ;
YAUGER, WL .
JOURNAL OF CHROMATOGRAPHY, 1968, 38 (04) :467-&
[6]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[7]   SIMULTANEOUS DETERMINATION OF PENTACHLOROPHENOL AND NEUTRAL ORGANOCHLORINE COMPOUNDS IN HUMAN-MILK [J].
BUTTE, W ;
FOOKEN, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (06) :511-514
[8]   DETERMINATION OF PENTACHLOROPHENOL (PCP) IN HUMAN-SERUM AND URINE USING TRIETHYLSULFONIUM HYDROXIDE FOR PYROLYTIC ETHYLATION [J].
BUTTE, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (05) :449-452
[9]  
DAS JV, 1994, CHEM ANAL-WARSAW, V39, P693
[10]  
DAVIES JEW, 1973, LAB PRACT, V22, P20