Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise - Part I: Conventional techniques

被引:103
作者
Warburton, DER
Haykowsky, MJF
Quinney, HA
Humen, DP
Teo, KK
机构
[1] Univ Alberta, Fac Phys Educ & Sport Studies, Phys Educ Ctr, Edmonton, AB T6G 2H9, Canada
[2] Univ Alberta, Div Cardiol, Edmonton, AB, Canada
关键词
D O I
10.2165/00007256-199927010-00003
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The assessment of cardiac function, particularly cardiac output (Q) during heavy exercise is essential for the evaluation of cardiovascular factors that might limit oxygen transport. A series of invasive and noninvasive techniques has been developed for the assessment and monitoring of if during resting and submaximal exercise conditions. However, very few techniques have been found to give accurate and reliable determinations of (Q) over dot during Vigorous to maximum exercise. For exercise physiologists and sport cardiologists, maximal exercise data are of primary importance. The 'gold standard' measures of cardiac function are considered to be the direct Fick and dye-dilution methods. These have been widely shown to give accurate and reliable determinations of (Q) over dot during resting and submaximal exercise conditions; however, their use during maximal exercise conditions is debatable due to the inherent risks involved with each and their increasing inaccuracy during the later stages of vigorous exercise. Thermodilution has also been considered to be a relatively good method for the determination of (Q) over dot during rest and exercise conditions, but recent authors have questioned its use due to the nature of the measure and its inaccuracy during strenuous exercise. Various noninvasive measures of cardiac function have been developed to overcome the problems associated with the 'gold standard' measures. The first part of this article discusses conventional techniques used in exercise physiology settings. The majority of these provide accurate and reliable determinations of (Q) over dot during rest and submaximal exercise. However, very few techniques are suitable for maximal exercise conditions. Perhaps only the foreign gas rebreathe using acetylene (C2H2) meets all the criteria of being noninvasive, simple to use, reliable over repeated measurements, accurate and useful during maximal exercise.
引用
收藏
页码:23 / 41
页数:19
相关论文
共 111 条
[71]  
MCHARDY GJR, 1967, CLIN SCI, V32, P299
[72]   Changes in stroke volume and maximal aerobic capacity with increased blood volume in men and women [J].
Mier, CM ;
Domenick, MA ;
Turner, NS ;
Wilmore, JH .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (04) :1180-1186
[73]  
MILLER E, 1962, J LAB CLIN MED, V59, P345
[74]   EVALUATION USING DOGS OF A METHOD FOR ESTIMATING MIXED VENOUS AND ARTERIAL PCO2 FROM A SINGLE BREATH [J].
MOHAMMED, MMJ ;
HAINSWORTH, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 50 (01) :196-199
[75]   EVALUATION USING DOGS OF A METHOD FOR ESTIMATING CARDIAC-OUTPUT FROM A SINGLE BREATH [J].
MOHAMMED, MMJ ;
WOOD, LM ;
HAINSWORTH, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 50 (01) :200-202
[76]   COMPARISON OF CO2-REBREATHING AND DIRECT FICK METHODS FOR DETERMINING CARDIAC OUTPUT [J].
MUIESAN, G ;
SORBINI, CA ;
SOLINAS, E ;
GRASSI, V ;
CASUCCI, G ;
PETZ, E .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (03) :424-&
[77]  
NICHOLSON JW, 1951, J LAB CLIN MED, V38, P588
[78]   EVALUATION OF A MODIFIED ACETYLENE REBREATHING METHOD FOR THE DETERMINATION OF CARDIAC-OUTPUT [J].
NYSTROM, J ;
CELSING, F ;
CARLENS, P ;
EKBLOM, B ;
RING, P .
CLINICAL PHYSIOLOGY, 1986, 6 (03) :253-268
[79]   COMPARISON OF METHODS TO CALCULATE CARDIAC-OUTPUT USING CO2 REBREATHING METHOD [J].
PATERSON, DH ;
CUNNINGHAM, DA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1976, 35 (03) :223-230
[80]   THE ACCURACY AND RESPONSE CHARACTERISTICS OF A SIMPLIFIED EAR OXIMETER [J].
REBUCK, AS ;
CHAPMAN, KR ;
DURZO, A .
CHEST, 1983, 83 (06) :860-864