Electro-osmotic flow in porous media using magnetic resonance imaging

被引:12
作者
Locke, BR [1 ]
Acton, M
Gibbs, SJ
机构
[1] Florida State Univ, Coll Engn, FAMU, Dept Chem Engn, Tallahassee, FL 32310 USA
[2] Florida State Univ, Natl High Magnet Field Lab, Ctr Interdisciplinary Magnet Resonance, Tallahassee, FL 32310 USA
关键词
D O I
10.1021/la0016928
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Magnetic resonance imaging (MRI) has been used to study electro-osmotic flow in a porous medium consisting of spherical glass particles ranging from 2.0 to 4.0 min in diameter. Electrodes placed at each end of a 1-cm glass tube containing the spheres and solution were used to generate flow. Pulsed field gradient MRI at 500 and 600 MHz was used to measure the fluid velocity fields and provided in-plane image resolution of approximately 78 x 78 mum(2) for 100 mum thick slices. Velocity fields as functions of applied voltage were measured for four cases: (1) empty tube with open ends, (2) empty tube with closed ends, (3) tube with packing and closed ends, and (4) tube with packing and open ends. Both closed-tube systems showed recirculation; in the closed tube with particles, recirculation occurred over the length scale of a single particle. The standard deviation or spread of the velocity distribution for the closed-tube experiments scaled approximately linearly with increasing applied voltage, while the velocity mean remained approximately zero. In the open-tube system, both the mean velocity and the standard deviation of the velocity distribution scaled linearly with the applied voltage. Detailed analyses of the velocity distribution histograms show discrepancies with predictions of the bundled-capillary tube, model of electro-osmotic flow in porous media.
引用
收藏
页码:6771 / 6781
页数:11
相关论文
共 58 条
[41]   Capillary electrochromatography: theories on electroosmotic flow in porous media [J].
Rathore, AS ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :185-195
[42]   Electrically-assisted transdermal drug delivery [J].
Riviere, JE ;
Heit, MC .
PHARMACEUTICAL RESEARCH, 1997, 14 (06) :687-697
[43]  
RUBINSTEIN I, 1999, SURFACE CHEM ELECTRO, P591
[44]   Reverse iontophoresis - Parameters determining electroosmotic flow .1. pH and ionic strength [J].
Santi, P ;
Guy, RH .
JOURNAL OF CONTROLLED RELEASE, 1996, 38 (2-3) :159-165
[45]   ANOMALOUS EFFECTS DURING ELECTROLYTE OSMOSIS ACROSS CHARGED POROUS MEMBRANES [J].
SASIDHAR, V ;
RUCKENSTEIN, E .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1982, 85 (02) :332-362
[46]  
Saville D. A., 1980, PHYSICOCHEM HYDRODYN, V1, P297
[47]   REMOVAL OF CONTAMINANTS FROM SATURATED CLAY BY ELECTROOSMOSIS [J].
SHAPIRO, AP ;
PROBSTEIN, RF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (02) :283-291
[48]   SKIN ALTERATION AND CONVECTIVE SOLVENT FLOW EFFECTS DURING IONTOPHORESIS .1. NEUTRAL SOLUTE TRANSPORT ACROSS HUMAN SKIN [J].
SIMS, SM ;
HIGUCHI, WI ;
SRINIVASAN, V .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1991, 69 (02) :109-121
[49]  
SMOLUCHOWSKI M, 1918, Z PHYS CHEM, V93, P129
[50]  
Soderman O, 1996, J CHEM PHYS, V105, P10300, DOI 10.1063/1.472958