Optical sensor array and integrated light source

被引:70
作者
Cho, EJ [1 ]
Bright, FV [1 ]
机构
[1] SUNY Buffalo, Dept Chem, Buffalo, NY 14260 USA
关键词
D O I
10.1021/ac010051u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a new, solid-state, integrated optical array sensor platform. The optical sensor array and integrated light source (OSAILS) is demonstrated for quenchometric O-2 detection. The OSAILS requires low voltages (3-5 V dc), it is stable (less than or equal to5% RSD over the course of several hours of continuous operation), it is reproducible and reversible (less than or equal to3% RSD), it exhibits a rapid response time (<30 s), and it provides good detection limits (0.2% O-2). The OSAILS opens the door to a number of new optical sensor array strategies.
引用
收藏
页码:3289 / 3293
页数:5
相关论文
共 82 条
  • [1] Cross-reactive chemical sensor arrays
    Albert, KJ
    Lewis, NS
    Schauer, CL
    Sotzing, GA
    Stitzel, SE
    Vaid, TP
    Walt, DR
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2595 - 2626
  • [2] ANISIMKIN VI, 1998, P IEEE ULTRAOSN S, V1, P529
  • [3] FIBEROPTIC CHEMICAL SENSORS
    ARNOLD, MA
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (21) : A1015 - A1025
  • [4] ENZYMES AND OTHER PROTEINS ENTRAPPED IN SOL-GEL MATERIALS
    AVNIR, D
    BRAUN, S
    LEV, O
    OTTOLENGHI, M
    [J]. CHEMISTRY OF MATERIALS, 1994, 6 (10) : 1605 - 1614
  • [5] DETERMINATION OF OXYGEN CONCENTRATIONS BY LUMINESCENCE QUENCHING OF A POLYMER-IMMOBILIZED TRANSITION-METAL COMPLEX
    BACON, JR
    DEMAS, JN
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (23) : 2780 - 2785
  • [6] BAILEY RA, 2000, POLYM SENSORS ACTUAT, P149
  • [7] Application of fuzzy clustering and piezoelectric chemical sensor array for investigation on organic compounds
    Barkó, G
    Abonyi, J
    Hlavay, J
    [J]. ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) : 219 - 226
  • [8] Using intrinsic fluorescence to investigate proteins entrapped in sol-gel derived materials
    Brennan, JD
    [J]. APPLIED SPECTROSCOPY, 1999, 53 (03) : 106A - 121A
  • [9] Multiple-input microcantilever sensors
    Britton, CL
    Jones, RL
    Oden, PI
    Hu, Z
    Warmack, RJ
    Smith, SF
    Bryan, WL
    Rochelle, JM
    [J]. ULTRAMICROSCOPY, 2000, 82 (1-4) : 17 - 21
  • [10] All-solid state miniaturized fluorescence sensor array for the determination of critical gases and electrolytes in blood
    Bruno, AE
    Barnard, S
    Rouilly, M
    Waldner, A
    Berger, J
    Ehrat, M
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (03) : 507 - 513