Artifacts in 3-T MRI: Physical background and reduction strategies

被引:206
作者
Dietrich, Olaf [1 ]
Reiser, Maximilian F. [1 ]
Schoenberg, Stefan O. [2 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Heidelberg Univ, Univ Hosp Mannheim, Med Fac Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
关键词
magnetic resonance imaging; 3-T MRI; high-field MRI; image artifacts;
D O I
10.1016/j.ejrad.2007.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Magnetic resonance imaging (MRI) at a field-strength of 3 T has become more and more frequently used in recent years. In an increasing number of radiological sites, 3-T MRI now starts to play the same role for clinical imaging that was occupied by 1.5-T systems in the past. Because of physical limitations related to the higher field strength and because of protocols transferred from 1.5-T MRI that are not yet fully optimized for 3 T, radiologists and technicians working at these systems are relatively often confronted with image artifacts related to 3-T MRI. The purpose of this review article is to present the most relevant artifacts that arise in 3-T MRI, to provide some physical background on the formation of artifacts, and to suggest strategies to reduce or avoid these artifacts. The discussed artifacts are classified and ordered according to the physical mechanism or property of the MRI system responsible for their occurrence: artifacts caused by B-0 inhomogeneity and susceptibility effects, B, inhomogeneity and wavelength effects, chemical-shift effects, blood flow and magnetohydrodynamics, and artifacts related to SNR. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 40 条
[1]
MODIFIED ITERATIVE MODEL BASED ON DATA EXTRAPOLATION METHOD TO REDUCE GIBBS RINGING [J].
AMARTUR, S ;
HAACKE, EM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :307-317
[2]
Imaging artifacts at 3.OT [J].
Bernstein, Matt A. ;
Huston, John, III ;
Ward, Heidi A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) :735-746
[3]
Central brightening due to constructive interference with, without, and despite dielectric resonance [J].
Collins, CM ;
Liu, WZ ;
Schreiber, W ;
Yang, QX ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :192-196
[4]
Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies [J].
Collins, CM ;
Liu, W ;
Swift, BJ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) :1327-1332
[5]
Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency [J].
Deshpande, VS ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :803-809
[6]
THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING [J].
EDELSTEIN, WA ;
GLOVER, GH ;
HARDY, CJ ;
REDINGTON, RW .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :604-618
[7]
Fenchel Michael, 2007, Top Magn Reson Imaging, V18, P95, DOI 10.1097/RMR.0b013e3180f617af
[8]
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[9]
2-9
[10]
RF aitifacts caused by metallic implants or instruments which get more prominent at 3 T: an in vitro study [J].
Graf, H ;
Lauer, UA ;
Berger, A ;
Schick, F .
MAGNETIC RESONANCE IMAGING, 2005, 23 (03) :493-499