Central brightening due to constructive interference with, without, and despite dielectric resonance

被引:174
作者
Collins, CM [1 ]
Liu, WZ [1 ]
Schreiber, W [1 ]
Yang, QX [1 ]
Smith, MB [1 ]
机构
[1] Penn State Univ, Coll Med, Dept Radiol H066, Ctr NMR Res, Hershey, PA 17033 USA
关键词
calculations; B-1; dielectric resonance; MRI; interference; surface coil;
D O I
10.1002/jmri.20245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To aid in discussion about the mechanism for central brightening in high field magnetic resonance imaging (MRI). especially regarding the appropriateness of using the term dielectric resonance to describe the central brightening seen in images of the human head. Materials and Methods: We present both numerical calculations and experimental images at 3 T of a 35-cm-diameter spherical phantom of varying salinity both with one surface coil and with two surface coils on opposite sides. and further numerical calculations at frequencies corresponding to dielectric resonances for the sphere. Results: With two strategically placed surface coils it is possible to create central brightening even when one coil alone excites an image intensity pattern either bright on one side only or bright on both sides with central darkening. This central brightening can be created with strategic coil placement even when the resonant pattern would favor central darkening. Results in a conductive sample show that central brightening can similarly be achieved in weakly conductive dielectric materials where any true resonances would be heavily damped. such as in human tissues. Conclusion: Constructive interference and wavelength effects are likely bigger contributors to central brightening in MR images of weakly conductive biological samples than is true dielectric resonance.
引用
收藏
页码:192 / 196
页数:5
相关论文
共 17 条
[1]   Radio frequency magnetic field mapping of a 3 tesla birdcage coil: Experimental and theoretical dependence on sample properties [J].
Alecci, M ;
Collins, CM ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :379-385
[2]  
Barfuss H, 1990, NMR Biomed, V3, P31, DOI 10.1002/nbm.1940030106
[3]  
Bomsdorf H, 1988, NMR Biomed, V1, P151, DOI 10.1002/nbm.1940010308
[4]   Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz [J].
Collins, CM ;
Yang, QX ;
Wang, JH ;
Zhang, X ;
Liu, H ;
Michaeli, S ;
Zhu, XH ;
Adriany, G ;
Vaughan, JT ;
Anderson, P ;
Merkle, H ;
Ugurbil, K ;
Smith, MB ;
Chen, W .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :1026-1028
[5]   Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil [J].
Collins, CM ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :684-691
[6]  
GASTINE M, 1997, IEEE T MICROW THEORY, V15, P694
[7]   Dielectric resonances and B1 field inhomogeneity in UHFMRI:: computational analysis and experimental findings [J].
Ibrahim, TS ;
Lee, R ;
Abduljalil, AM ;
Baertlein, BA ;
Robitaille, PML .
MAGNETIC RESONANCE IMAGING, 2001, 19 (02) :219-226
[8]   Dielectric resonance phenomena in ultra high field MRI [J].
Kangarlu, A ;
Baertlein, BA ;
Lee, R ;
Ibrahim, TS ;
Yang, LN ;
Abduljalil, AM ;
Robitaille, EML .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (06) :821-831
[9]   Ultimate intrinsic signal-to-noise ratio in MRI [J].
Ocali, O ;
Atalar, E .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) :462-473
[10]  
ROSCHMANN P, 2000, P 8 ANN M ISMRM DENV, P151