Comparative experiment study on photovoltaic and thermal solar system under natural circulation of water

被引:143
作者
He, Wei [1 ]
Zhang, Yang [1 ]
Ji, Jie [1 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
关键词
PV/T system; Comparative experiment; Thermal efficiency; Electrical efficiency; Primary-energy saving efficiency; COLLECTOR;
D O I
10.1016/j.applthermaleng.2011.06.021
中图分类号
O414.1 [热力学];
学科分类号
070201 [理论物理];
摘要
The hybrid photovoltaic and thermal (PV/T) system can utilize solar energy more effectively and has a higher total efficiency compared with a traditional solar collecting system and a photovoltaic (PV) module. However, there is limited experimental data on how much energy the PV/T system can save when operating with same area of a PV plate and a solar collector simultaneously. In this paper, a comparative test rig had been set up to measure and analyze the performance of PV/T system. There were monocrystalline silicon PV/T solar collector, a traditional solar collector and a monocrystalline silicon photovoltaic plate. The PV/T collector and the traditional solar collector had the same collecting areas and solar cell covered area of the PV/T collector was the same as the area of the photovoltaic plate. The experimental results showed that the daily thermal efficiency of PV/T system was about 40%, which was about 75% of that for a traditional solar thermosiphon system, and the daily average electrical efficiency was found about 10%, which was a little lower than the photovoltaic module. But primary-energy saving efficiency of the PV/T system was much higher than that of the individual PV plate and the traditional solar collector. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3369 / 3376
页数:8
相关论文
共 15 条
[1]
Model calculations on a flat-plate solar heat collector with integrated solar cells [J].
Bergene, T ;
Lovvik, OM .
SOLAR ENERGY, 1995, 55 (06) :453-462
[2]
Chapin D.M., 1955, BELL LAB REC, V33, P214
[3]
Photovoltaic thermal (PV/T) collectors: A review [J].
Charalambous, P. G. ;
Maidment, G. G. ;
Kalogirou, S. A. ;
Yiakoumetti, K. .
APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) :275-286
[4]
Computer modeling and experimental validation of a building-integrated photovoltaic and water heating system [J].
Chow, T. T. ;
He, W. ;
Chan, A. L. S. ;
Fong, K. F. ;
Lin, Z. ;
Ji, J. .
APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) :1356-1364
[5]
An experimental study of facade-integrated photovoltaic/water-heating system [J].
Chow, T. T. ;
He, W. ;
Ji, J. .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :37-45
[6]
Performance analysis of photovoltaic-thermal collector by explicit dynamic model [J].
Chow, TT .
SOLAR ENERGY, 2003, 75 (02) :143-152
[7]
Thermal modeling of a combined system of photovoltaic thermal (PV/T) solar water heater [J].
Dubey, Swapnil ;
Tiwari, G. N. .
SOLAR ENERGY, 2008, 82 (07) :602-612
[8]
Hybrid photovoltaic and thermal solar-collector designed for natural circulation of water [J].
He, W ;
Chow, TT ;
Ji, J ;
Lu, JP ;
Pei, G ;
Chan, LS .
APPLIED ENERGY, 2006, 83 (03) :199-210
[9]
A PERFORMANCE-TEST METHOD OF SOLAR THERMOSIPHON SYSTEMS [J].
HUANG, BJ ;
DU, SC .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (03) :172-179
[10]
Performance evaluation of solar photovoltaic/thermal systems [J].
Huang, BJ ;
Lin, TH ;
Hung, WC ;
Sun, FS .
SOLAR ENERGY, 2001, 70 (05) :443-448