Imaging capabilities of synchrotron infrared microspectroscopy

被引:81
作者
Dumas, P
Jamin, N
Teillaud, JL
Miller, LM
Beccard, B
机构
[1] Ctr Univ Paris Sud, LURE CNRS, F-91898 Orsay, France
[2] CEA Saclay, DBJC, F-91191 Gif Sur Yvette, France
[3] CNRS, URA 2096, F-91191 Gif Sur Yvette, France
[4] Ctr Rech Biomed Cordeliers, INSERM, Unite 255, F-75270 Paris 06, France
[5] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
[6] Thermo Nicolet, F-78180 Montigny Le Bretonneux, France
关键词
D O I
10.1039/b305065c
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
It has become increasingly clear that synchrotron infrared micro-spectroscopy is an extremely valuable analysis tool when determining the chemical composition of biological and biomedical samples, at the diffraction-limited spatial resolution. Highly resolved infrared micro-spectroscopy, together with the high signal-to-noise level of the recorded spectra, is essential in generating chemical and statistical (multivariate) images. This is illustrated in the case of individual cell and hair section studies. Unprecedented chemical images of lipid distribution and secondary structure relative concentration have been achieved using the synchrotron source. A comparison with a Focal plane Array imaging system, on the same hair section, shows that, despite the fast imaging processing and improved quality achieved with the focal plane array detectors, spectral quality is markedly superior in the case of the synchrotron source. It is clear that the two approaches could be very complementary if combined on the same sample area, in a synchrotron facility.
引用
收藏
页码:289 / 302
页数:14
相关论文
共 33 条
[1]  
BERTRAND L, 2003, BIOPHYS ACTA, V218, P1620
[2]   Long-wavelength radiation along a straight-section axis in an electron storage ring [J].
Bosch, RA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 386 (2-3) :525-530
[3]   Characterization of the new NSLS infrared microspectroscopy beamline U10B [J].
Carr, GL ;
Merlo, O ;
Munsli, M ;
Springer, S ;
Ho, SC .
ACCELERATOR-BASED SOURCES OF INFRARED AND SPECTROSCOPIC APPLICATIONS, 1999, 3775 :22-28
[4]   Resolution limits for infrared microspectroscopy explored with synchrotron radiation [J].
Carr, GL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (03) :1613-1619
[5]   VARIABILITY IN CHEMICAL COMPOSITION OF HUMAN SKIN SURFACE LIPIDS [J].
DOWNING, DT ;
STRAUSS, JS ;
POCHI, PE .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1969, 53 (05) :322-&
[6]  
DUMAS P, 2003, IN PRESS VIB SPECTRO
[7]   INFRARED SYNCHROTRON RADIATION FROM ELECTRON STORAGE-RINGS [J].
DUNCAN, WD ;
WILLIAMS, GP .
APPLIED OPTICS, 1983, 22 (18) :2914-2923
[8]   ORIENTED STRUCTURE IN HUMAN STRATUM-CORNEUM REVEALED BY X-RAY-DIFFRACTION [J].
GARSON, JC ;
DOUCET, J ;
LEVEQUE, JL ;
TSOUCARIS, G .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1991, 96 (01) :43-49
[9]  
Harris P., 1994, METHOD MOL BIOL, V22, P183
[10]   THE USE AND MISUSE OF FTIR SPECTROSCOPY IN THE DETERMINATION OF PROTEIN-STRUCTURE [J].
JACKSON, M ;
MANTSCH, HH .
CRITICAL REVIEWS IN BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1995, 30 (02) :95-120