Preliminary investigation of near-infrared spectroscopic measurements of urea, creatinine, glucose, protein, and ketone in urine

被引:67
作者
Pezzaniti, JL [1 ]
Jeng, TW [1 ]
McDowell, L [1 ]
Oosta, GM [1 ]
机构
[1] Abbott Labs, Div Diagnost, Abbott Pk, IL 60064 USA
关键词
urinalysis; urine; spectroscopy; infrared; near-infrared; visible; Fourier transform;
D O I
10.1016/S0009-9120(01)00198-9
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: We investigated the use of near-infrared spectroscopy as an analytical tool to quantify concentrations of urea, creatinine, glucose, ketone, and protein in urine. Design and Methods: FT-IR spectroscopy in conjunction with a polynomial based spectral smoothing method was applied to urine specimens. A partial factorial experimental design was employed to collect spectra using normal and spiked urine samples. Results: Our results show that the spectral signatures of urea, creatinine, glucose, ketone, and protein in the 1350 to 1800 nm and 2050 to 2375 nm range are sufficiently strong and unique for accurate measurements. Conclusions: The accuracy of near infrared for quantifying concentrations of urea and creatinine is only slightly less than our selected reference methods. Glucose, ketone and protein are sufficiently accurate to be useful as a screening tool for wellness. The method successfully accounts for biologic matrix variation. The advantages of near-infrared analysis are (1) no reagents, (2) ease of sample preparation, (3) speed, and (4) the ability to quantify multiple analytes with one spectra. (C) 2001 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 20 条
[11]  
LIN CT, 1990, DRUG INF J, V24, P671
[12]  
Low P S, 1978, J Singapore Paediatr Soc, V20, P37
[13]   SIGNAL-TO-NOISE RATIO IN HIGHER-ORDER DERIVATIVE SPECTROMETRY [J].
OHAVER, TC ;
BEGLEY, T .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1876-1878
[14]   Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides [J].
Pan, ST ;
Chung, H ;
Arnold, MA ;
Small, GW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1124-1135
[15]  
PEUCHANT E, 1988, CLIN CHEM, V34, P5
[16]   Quantitation of protein, creatinine, and urea in urine by near-infrared spectroscopy [J].
Shaw, RA ;
Kotowich, S ;
Mantsch, HH ;
Leroux, M .
CLINICAL BIOCHEMISTRY, 1996, 29 (01) :11-19
[17]   COMPARISON OF MULTIVARIATE CALIBRATION METHODS FOR QUANTITATIVE SPECTRAL-ANALYSIS [J].
THOMAS, EV ;
HAALAND, DM .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1091-1099
[18]  
VANTOORENENBERGEN AW, 1994, CLIN CHEM, V40, P1788
[19]  
VOSWINCKEL P, 1994, KIDNEY INT, pS3
[20]  
WATSON ID, 1992, CLIN CHEM, V38, P441