Solid-phase capture of proteins, spores, and bacteria

被引:30
作者
Weimer, BC [1 ]
Walsh, MK [1 ]
Beer, C [1 ]
Koka, R [1 ]
Wang, X [1 ]
机构
[1] Utah State Univ, Ctr Microbe Detect & Physiol, Dept Nutr & Food Sci, Logan, UT 84322 USA
关键词
D O I
10.1128/AEM.67.3.1300-1307.2001
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Current methods for the detection of pathogens in food and water samples generally require a preenrichment step that allows selective enrichment of the test organism. The objective of this research was to eliminate an enrichment step to allow detection of bacteria directly in food and water samples in 30 min. A high-flow-rate, fluidized bed to capture and concentrate large (bacteria and spores) and small (protein) molecules was developed. This format, ImmunoFlow, is volume independent and uses large beads (greater than 3 mm in diameter) when capturing bacteria to prevent sample clogging when testing food samples. Detection of bound targets was done using existing enzyme-linked immunosorbent assay (ELISA) protocols. Four antibodies (anti- Escherichia coli O157:H7, -Bacillus globigii, -bovine serum albumin [BSA], and -ovalbumin [OVA]) were covalently coupled to various glass and ceramic beads. Very small amounts of BSA (<1 ng) and OVA (0.2 to 4.0 <mu>g) were detected. Various industrial and environmental samples were used to observe the effect of the sample composition on the capture of anti-B. globigii and anti-E. coli O157:H7 modified beads. The lower limit of detection for both E. coli O157:H7 and B. globigii was 1 spore/cell independent of the sample size. The activity of anti-B. globigii modified beads declined after 3 days. Anti-E. coli O157:H7 modified beads declined in the capture ability after 2 days in various storage buffers. Storage temperature (4 and 25 degreesC) did not influence the stability. The ImmunoFlow technology is capable of capturing bacteria and spores directly from samples, with subsequent detection in an ELISA format in 30 min.
引用
收藏
页码:1300 / 1307
页数:8
相关论文
共 45 条
[1]   Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7 [J].
Abdel-Hamid, I ;
Ivnitski, D ;
Atanasov, P ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) :309-316
[2]   Efficacy of spray application of chlorinated water in killing pathogenic bacteria on raw apples, tomatoes, and lettuce [J].
Beuchat, LR ;
Nail, BV ;
Adler, BB ;
Clavero, MRS .
JOURNAL OF FOOD PROTECTION, 1998, 61 (10) :1305-1311
[3]   Immunomagnetic detection of Bacillus stearothermophilus spores in food and environmental samples [J].
Blake, MR ;
Weimer, BC .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1997, 63 (05) :1643-1646
[4]   Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli O157:H7 [J].
Brewster, JD ;
Mazenko, RS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 211 (1-2) :1-8
[5]  
Buchanan RL, 1998, APPL ENVIRON MICROB, V64, P4533
[6]   AROMATIC-AROMATIC INTERACTION - A MECHANISM OF PROTEIN-STRUCTURE STABILIZATION [J].
BURLEY, SK ;
PETSKO, GA .
SCIENCE, 1985, 229 (4708) :23-28
[7]   Use of commercial enzyme immunoassays and immunomagnetic separation systems for detecting Escherichia coli O157 in bovine fecal samples [J].
Chapman, PA ;
Malo, ATC ;
Siddons, CA ;
Harkin, M .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1997, 63 (07) :2549-2553
[8]  
CLAVERO MRS, 1995, APPL ENVIRON MICROB, V61, P3268
[9]   Survival of Escherichia coli O157:H7 in broth and processed salami as influenced by pH. Water activity, and temperature and suitability of media for its recovery [J].
Clavero, MRS ;
Beuchat, LR .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1996, 62 (08) :2735-2740
[10]  
Cray WC, 1998, APPL ENVIRON MICROB, V64, P1975