Do large femoral heads reduce the risks of impingement in total hip arthroplasty with optimal and non-optimal cup positioning?

被引:28
作者
Cinotti, Gianluca [1 ]
Lucioli, Niccolo [1 ]
Malagoli, Andrea [2 ]
Calderoli, Carlo [2 ]
Cassese, Ferdinando [2 ]
机构
[1] Univ Roma La Sapienza, Dept Orthopaed, Rome, Italy
[2] DTM Technol, Modena, Italy
关键词
DISLOCATION; MOTION; REPLACEMENT; DIAMETER; DESIGN; LINER; RANGE; SIZE;
D O I
10.1007/s00264-010-0954-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The purpose of this study was to assess whether large femoral heads (36-38 mm) improve the range of motion in total hip arthroplasty compared to standard (28-32 mm) femoral heads in the presence of optimal and non-optimal cup positioning. A mathematical model of the hip joint was generated by using a laser scan of a dried cadaveric hip. The range of motion was assessed with a cup inclination and anteversion of reference and with non-optimal cup positions. Large femoral heads increased the range of motion, compared to the 28-mm femoral head, in the presence of a hip prosthesis correctly implanted and even more so in the presence of non-optimal cup positioning. However, with respect to the 32-mm femoral head, large femoral heads showed limited benefits both in the presence of optimal and non-optimal cup positioning.
引用
收藏
页码:317 / 323
页数:7
相关论文
共 24 条
[1]
Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[2]
Stem design and dislocation after revision total hip arthroplasty - Clinical results and computer modeling [J].
Barrack, RL ;
Butler, RA ;
Laster, DR ;
Andrews, P .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :8-12
[3]
The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[4]
Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement [J].
Beaule, PE ;
Schmalzried, TP ;
Udomkiat, P ;
Amstutz, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :256-263
[5]
Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11) :2456-2463
[6]
Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[7]
The elevated-rim acetabular liner in total hip arthroplasty: Relationship to postoperative dislocation [J].
Cobb, TK ;
Morrey, BF ;
Ilstrup, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (01) :80-86
[8]
Biomechanics of large femoral heads - What they do and don't do [J].
Crowninshield, RD ;
Maloney, WJ ;
Wentz, DH ;
Humphrey, SM ;
Blanchard, CR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :102-107
[9]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[10]
DORR LD, 1983, CLIN ORTHOP RELAT R, P151