Comparison of three measures of the ankle-brachial blood pressure index in a general population

被引:46
作者
Pan, Cheng-Rui
Staessen, Jan A.
Li, Yan
Wang, Ji-Guang
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Ctr Epidemiol Studies & Clin Trials, Shanghai 200030, Peoples R China
[2] Univ Leuven, Dept Cardiovasc Dis, Div Hypertens & Cardiovasc Rehabil, Studies Coordinating Ctr, Louvain, Belgium
关键词
arteries; blood pressure; epidemiology; population;
D O I
10.1291/hypres.30.555
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The ankle-brachial blood pressure index (ABI) predicts cardiovasular disease. To our knowledge, no study has compared manual ABI measurements with an automated electronic oscillometric method in a population sample. We enrolled 946 residents (50.8% women; mean age, 43.5 years) from 8 villages in JingNing County, Zhejiang Province, P.R. China. We computed ABI as the ratio of ankle-to-arm systolic blood pressures from consecutive auscultatory or Doppler measurements at the posterior tibial and brachial arteries. We also used an automated oscillometric technique with simultaneous ankle and arm measurements (Colin VP-1000). Mean ABI values were significantly higher on Doppler than auscultatory measurements (1.15 vs. 1.07; p<0.0001) with intermediate levels on oscillometric determination (1.12; p<0.0001 vs. Doppler). The differences among the three measurements were not homogeneously distributed across the range of ABI values. Doppler and oscillometric ABIs were similar below 1.0, whereas above 1.2 Doppler and auscultatory ABIs were comparable. In Bland and Altman plots, the correlation coefficient between differences in Doppler minus oscillometric ABI and ABI level was 0.21 (p<0.0001). The corresponding correlation coefficient for Doppler minus auscultatory ABI was -0.13 (p<0.0001). In conclusion, automated ABI measurements are feasible in large-scale population studies. However, the small differences in ABI values between manual and oscillometric measurements depend on ABI level and must be considered in the interpretation of study results.
引用
收藏
页码:555 / 561
页数:7
相关论文
共 24 条
[1]  
ADISESHIAH M, 1987, ANN ROY COLL SURG, V69, P271
[2]   Automated oscillometric determination of the ankle - Brachial index provides accuracy necessary for office practice [J].
Beckman, JA ;
Higgins, CO ;
Gerhard-Herman, M .
HYPERTENSION, 2006, 47 (01) :35-38
[3]   Critical issues in peripheral arterial disease detection and management - A call to action [J].
Belch, JJF ;
Topol, EJ ;
Agnelli, G ;
Bertrand, M ;
Califf, RM ;
Clement, DL ;
Creager, MA ;
Easton, JD ;
Gavin, JR ;
Greenland, P ;
Hankey, G ;
Hanrath, P ;
Hirsch, AT ;
Meyer, J ;
Smith, SC ;
Sullivan, F ;
Weber, MA .
ARCHIVES OF INTERNAL MEDICINE, 2003, 163 (08) :884-892
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   A now device for automatic measurements of arterial stiffness and ankle-brachial index [J].
Cortez-Cooper, MY ;
Supak, JA ;
Tanaka, H .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (12) :1519-1522
[6]   Sensitivity and specificity of the ankle-brachial index to predict future cardiovascular outcomes - A systematic review [J].
Doobay, AV ;
Anand, SS .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2005, 25 (07) :1463-1469
[7]   Ankle brachial index as a marker of atherosclerosis in Chinese patients with high cardiovascular risk [J].
Hasimu, B ;
Li, J ;
Nakayama, T ;
Yu, JM ;
Yang, JG ;
Li, XK ;
Hu, DY .
HYPERTENSION RESEARCH, 2006, 29 (01) :23-28
[8]   The influence of experience on the reproducibility of the ankle-brachial systolic pressure ratio in peripheral arterial occlusive disease [J].
Kaiser, V ;
Kester, ADM ;
Stoffers, HEJH ;
Kitslaar, PJEHM ;
Knottnerus, JA .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 18 (01) :25-29
[9]   Does the clinical examination predict lower extremity peripheral arterial disease? [J].
Khan, NA ;
Rahim, SA ;
Anand, SS ;
Simel, DL ;
Panju, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (05) :536-546
[10]   Patient characteristics and factors associated with inter-arm difference of blood pressure measurements in a general population in Ohasama, Japan [J].
Kimura, A ;
Hashimoto, J ;
Watabe, D ;
Takahashi, H ;
Ohkubo, T ;
Kikuya, M ;
Imai, Y .
JOURNAL OF HYPERTENSION, 2004, 22 (12) :2277-2283