Mechanical response of tendon subsequent to ramp loading to varying strain limits

被引:20
作者
Devkota, AC
Weinhold, PS
机构
[1] Univ N Carolina, Orthopaed Res Lab, Dept Orthopaed, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
关键词
tendon; elastic limit; mechanical properties; subfailure injury; video strain analysis;
D O I
10.1016/S0268-0033(03)00168-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To determine the in vitro elastic limit of avian flexor tendons utilizing more current methodologies. Design. Assess the mechanical changes between subfailure and subsequent failure ramps at various loading levels. Background. Currently accepted values of elastic strain limits were determined utilizing older methodologies. Consequently, reported values are fairly small and imply matrix damage occurs with small strains. Methods. Flexor tendons were loaded in vitro, to various subfailure strain levels between 1% and 14%, allowed to rest for 5 min, then taken to failure. Suture markers, across the midsubstance, and cryo-grip displacement were monitored for strain using a video strain analysis system and a linear variable displacement transducer, respectively. The mechanical changes between the various subfailure and failure ramp loadings were assessed. Results. Varying strains of subfailure ramp loading did not influence (P > 0.05) the ultimate tensile failure strength, elastic modulus, strain at failure, or strain energy density of tendons. In addition, residual strain after subfailure loading was not significant, nor was it influenced by the level of the subfailure loading. Conclusions. Tendon behaves elastically under ramp loading to significantly higher strains (nearly failure) than previously reported (4%). Relevance This study has found strain thresholds required to cause matrix damage to be significantly higher than previously thought, implying that matrix changes to acute loading events are more a result of the cellular response to the loading event. The clinical relevance is that the clinician may have a greater opportunity to prevent matrix changes than once thought by biochemically altering the cellular response. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:969 / 974
页数:6
相关论文
共 23 条
[1]   MECHANICAL BEHAVIOUR OF TENDON IN VITRO - A PRELIMINARY REPORT [J].
ABRAHAMS, M .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (05) :433-+
[2]   PDGF-BB, IGF-I and mechanical load stimulate DNA synthesis in avian tendon fibroblasts in vitro [J].
Banes, AJ ;
Tsuzaki, M ;
Hu, PQ ;
Brigman, B ;
Brown, T ;
Almekinders, L ;
Lawrence, WT ;
Fischer, T .
JOURNAL OF BIOMECHANICS, 1995, 28 (12) :1505-1513
[3]   EFFECTS OF STRUCTURE AND STRAIN-MEASUREMENT TECHNIQUE ON THE MATERIAL PROPERTIES OF YOUNG HUMAN TENDONS AND FASCIA [J].
BUTLER, DL ;
GROOD, ES ;
NOYES, FR ;
ZERNICKE, RF ;
BRACKETT, K .
JOURNAL OF BIOMECHANICS, 1984, 17 (08) :579-596
[4]   COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS [J].
BUTLER, DL ;
KAY, MD ;
STOUFFER, DC .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :425-432
[5]   A NEW OPTICAL-SYSTEM FOR THE DETERMINATION OF DEFORMATIONS AND STRAINS - CALIBRATION CHARACTERISTICS AND EXPERIMENTAL RESULTS [J].
DERWIN, KA ;
SOSLOWSKY, LJ ;
GREEN, WDK ;
ELDER, SH .
JOURNAL OF BIOMECHANICS, 1994, 27 (10) :1277-+
[6]  
DEVKOTA AC, 2001, ANN BIOMED ENG, V29, P35
[7]   SOME PRACTICAL NOTES ON ANATOMY OF CHICKEN TOE FOR SURGEON INVESTIGATORS [J].
FARKAS, LG ;
THOMSON, HG ;
MARTIN, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1974, 54 (04) :452-458
[8]   Effect of stress deprivation and cyclic tensile loading on the material and morphologic properties of canine flexor digitorum profundus tendon: An in vitro study [J].
Hannafin, JA ;
Arnoczky, SP ;
Hoonjan, A ;
Torzilli, PA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) :907-914
[9]   TEMPERATURE-DEPENDENCE OF THE TENSILE PROPERTIES OF INTERSPINAL LIGAMENTS OF SHEEP [J].
HASBERRY, S ;
PEARCY, MJ .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (01) :62-66
[10]   TENSILE AND VISCOELASTIC PROPERTIES OF HUMAN PATELLAR TENDON [J].
JOHNSON, GA ;
TRAMAGLINI, DM ;
LEVINE, RE ;
OHNO, K ;
CHOI, NY ;
WOO, SLY .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (06) :796-803