Determination of moxonidine in human plasma by liquid chromatography-electro spray ionisation-mass spectrometry

被引:15
作者
Zhao, LH
Ding, L
Wei, X
机构
[1] China Pharmaceut Univ, Ctr Instrumental Anal, Nanjing 210009, Peoples R China
[2] China Pharmaceut Univ, Dept Pharmaceut Anal, Nanjing 210009, Peoples R China
关键词
moxonidine; HPLC-ESI-MS; human plasma; pharmacokinetics;
D O I
10.1016/j.jpba.2005.06.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of moxonidine in human plasma. After the addition of clonidine-HCI, the internal standard (IS) and sodium hydrogen carbonate, plasma samples were extracted using 5 mL ethyl acetate. The compounds were separated on a Lichrospher ODS (5 mu m, 250 mm x 4.6 mm) column using an elution system of 10 mmol/L ammonium acetate buffer-methanol (20:80 v/v) as the mobile phase. Analytes were determined using electrospary ionization in a single quadrupole mass spectrometer. LC-ESI-MS was performed in the selected-ion monitoring (SIM) mode using target ions at m/z: 242.2 for moxonidine and m/z: 230.1 for the IS. The method has shown to be sensitive and specific by testing six different blank plasma batches. Linearity was established for the range of concentrations 0.01976-9.88 ng/mL with a coefficient of correlation (r) of 0.9999. The lower limit of quantification (LOQ) was identifiable and reproducible at 0.01976 ng/mL. The method has been successfully applied to study the pharmacokinetics of moxonidine in healthy male Chinese volunteers. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 9 条
  • [1] [Anonymous], GUID IND BIOAN METH
  • [2] Simultaneous determination of sibutramine and its N-desmethyl metabolites in human plasma by liquid chromatography-electrospray ionization-mass spectrometry -: Method and clinical applications
    Ding, L
    Hao, XY
    Huang, X
    Zhang, SQ
    [J]. ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) : 241 - 248
  • [3] High-performance liquid chromatographic method for the bioequivalence evaluation of desloratadine fumarate tablets in dogs
    Liu, LH
    Qi, ML
    Wang, P
    Li, HZ
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) : 1013 - 1019
  • [4] MARTIN R, 1992, J PHARM BIOMED ANAL, P323
  • [5] Determination of nimodipine in human plasma by a sensitive and selective liquid chromatography-tandem mass spectrometry method
    Qiu, F
    Chen, XY
    Li, XY
    Zhong, DF
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 291 - 297
  • [6] INFLUENCE OF FOOD ON THE ORAL BIOAVAILABILITY OF MOXONIDINE
    THEODOR, RA
    WEIMANN, HJ
    WEBER, W
    MULLER, M
    MICHAELIS, K
    [J]. EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 1992, 17 (01) : 61 - 66
  • [7] ZHANG Q, 1997, J PHARM ANAL, V17, P368
  • [8] Determination of scutellarin in rat plasma by high-performance liquid chromatography with ultraviolet detection
    Zhong, DF
    Yang, BH
    Chen, XY
    Li, K
    Xu, JH
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02): : 439 - 444
  • [9] Determination of vertilmicin in rat serum by high-performance liquid chromatography using 1-fluoro-2,4-dinitrobenzene derivatization
    Zhou, MJ
    Wei, GL
    Liu, YP
    Sun, YM
    Xiao, SH
    Lu, L
    Liu, CX
    Zhong, DF
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (01): : 43 - 48