Determination of vertilmicin in rat serum by high-performance liquid chromatography using 1-fluoro-2,4-dinitrobenzene derivatization

被引:28
作者
Zhou, MJ
Wei, GL
Liu, YP
Sun, YM
Xiao, SH
Lu, L
Liu, CX
Zhong, DF
机构
[1] Shenyang Pharmaceut Univ, Lab Drug Metab & Pharmacokinet, Shenyang 110016, Peoples R China
[2] Tianjin Inst Pharmaceut Res, Tianjin Key Lab Drug Metab & Pharmacokinet, Tianjin 300193, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 798卷 / 01期
基金
中国国家自然科学基金;
关键词
derivatization; LC; vertilmicin; 1-fluoro-2,4-dinitrobenzene;
D O I
10.1016/j.jchromb.2003.08.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure for the high-performance liquid chromatographic determination of vertilmicin in rat serum was described using pre-column derivatization. The serum proteins were precipitated with acetonitrile and vertilmicin in the supernatant was derivatized with 1-fluoro-2,4-dinitrobenzene. Etimicin was selected as the internal standard. The mobile phase consisted of methanol-20 MM ammonium acetate (80:20, v/v), and flow-rate was 0.9 ml/min. Ultraviolet detection was set at 365 nm. The reaction products were chromatographed on a C-18 column kept at 40degreesC. A good linearity was found in the range of 0.5-250 mug/ml. Both intra- and inter-day precisions of vertilmicin, expressed as the relative standard deviation, were less than 7.4%. Accuracy, expressed as the relative error, ranged from -0.1 to 3.6%. The mean absolute recovery of vertilmicin at three different concentrations was 92.5%. Serum volumes of 50 mul were sufficient for the determination of vertilmicin. The method was proved suitable for the pharmacokinetic study of vertilmicin in rats. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 20 条
[1]   Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods [J].
Almeida, AM ;
Castel-Branco, MM ;
Falcao, AC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02) :215-222
[2]   A COMPARISON OF THE HOMOGENEOUS ENZYME-IMMUNOASSAY AND POLARIZATION FLUOROIMMUNOASSAY OF GENTAMICIN [J].
ANDREWS, JM ;
WISE, R .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1984, 14 (05) :509-520
[3]   Quantification of gentamicin in Mueller-Hinton agar by high-performance liquid chromatography [J].
Arcelloni, C ;
Comuzzi, B ;
Vaiani, R ;
Paroni, R .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (01) :151-156
[4]  
BACK SE, 1979, CLIN CHEM, V25, P1222
[5]   MICRO-DETERMINATION OF TOBRAMYCIN IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
BARENDS, DM ;
ZWAAN, CL ;
HULSHOFF, A .
JOURNAL OF CHROMATOGRAPHY, 1981, 225 (02) :417-426
[6]   MICRO-DETERMINATION OF GENTAMICIN IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
BARENDS, DM ;
VANDERSANDT, JSF ;
HULSHOFF, A .
JOURNAL OF CHROMATOGRAPHY, 1980, 182 (02) :201-210
[7]   Fluorodensitometric evaluation of gentamicin from plasma and urine by high-performance thin-layer chromatography [J].
Bhogte, CP ;
Patravale, VB ;
Devarajan, PV .
JOURNAL OF CHROMATOGRAPHY B, 1997, 694 (02) :443-447
[8]  
BROMN SA, 1990, ASS OFF ANAL CHEM, V73, P479
[9]  
Cherlet M, 2000, J MASS SPECTROM, V35, P1342, DOI 10.1002/1096-9888(200011)35:11<1342::AID-JMS71>3.0.CO
[10]  
2-Y