Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods

被引:492
作者
Almeida, AM [1 ]
Castel-Branco, MM [1 ]
Falcao, AC [1 ]
机构
[1] Univ Coimbra, Fac Pharm, Pharmacol Lab, P-3000295 Coimbra, Portugal
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 774卷 / 02期
关键词
linear regression; heteroscedasticity; weighting schemes; bioanalytical methods;
D O I
10.1016/S1570-0232(02)00244-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When the assumption of homoscedasticity is not met for analytical data, a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line is to use weighted least squares linear regression (WLSLR). The purpose of the present paper is to stress the relevance of weighting schemes for linear regression analysis and to show how this approach can be useful in the bioanalytical field. The steps to be taken in the study of the linear calibration approach are described. The application of weighting schemes was shown by using a high-performance liquid chromatography method for the determination of lamotrigine in biological fluids as a practical example. By using the WLSLR, the accuracy of the analytical method was improved at the lower end of the calibration curve. Bioanalytical methods data analysis was improved by using the WLSLR procedure. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:215 / 222
页数:8
相关论文
共 21 条
  • [1] [Anonymous], 1990, 85101 ISO, P1
  • [2] METHOD VALIDATION IN THE BIOANALYTICAL LABORATORY
    BUICK, AR
    DOIG, MV
    JEAL, SC
    LAND, GS
    MCDOWALL, RD
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) : 629 - 637
  • [3] METHOD VALIDATION REVISITED - A CHEMOMETRIC APPROACH
    CARDONE, MJ
    WILLAVIZE, SA
    LACY, ME
    [J]. PHARMACEUTICAL RESEARCH, 1990, 7 (02) : 154 - 160
  • [4] Lamotrigine analysis in blood and brain by high-performance liquid chromatography
    Castel-Branco, MM
    Almeida, AM
    Falcao, AC
    Macedo, TA
    Caramona, MM
    Lopez, FG
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 755 (1-2): : 119 - 127
  • [5] Daniel WW., 1987, BIOSTATISTICS FDN AN, V4th ed., P367
  • [6] NON-CONSTANT VARIANCE REGRESSION TECHNIQUES FOR CALIBRATION-CURVE-BASED ANALYSIS
    GARDEN, JS
    MITCHELL, DG
    MILLS, WN
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (14) : 2310 - 2315
  • [7] Hartmann C, 1995, F I P PAPERBACK, P331
  • [8] BIOLOGICAL SAMPLE PREPARATION AND DATA REDUCTION CONCEPTS IN PHARMACEUTICAL ANALYSIS
    JOHNSON, EL
    REYNOLDS, DL
    WRIGHT, DS
    PACHLA, LA
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (08) : 372 - 379
  • [9] VALIDATION OF BIOANALYTICAL METHODS
    KARNES, HT
    SHIU, G
    SHAH, VP
    [J]. PHARMACEUTICAL RESEARCH, 1991, 8 (04) : 421 - 426
  • [10] A COMPREHENSIVE METHOD VALIDATION STRATEGY FOR BIOANALYTICAL APPLICATIONS IN THE PHARMACEUTICAL-INDUSTRY .1. EXPERIMENTAL CONSIDERATIONS
    LANG, JR