Simultaneous Quantification of Apolipoprotein A-I and Apolipoprotein B by Liquid-Chromatography-Multiple-Reaction-Monitoring Mass Spectrometry

被引:134
作者
Agger, Sean A. [1 ]
Marney, Luke C. [1 ]
Hoofnagle, Andrew N. [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Lab Med, Seattle, WA 98195 USA
关键词
PEPTIDE IMMUNOAFFINITY ENRICHMENT; QUANTITATION; PROTEIN; PROTEOMICS; BIOMARKER; SERUM; RISK; LIPOPROTEINS; MORTALITY; STANDARDS;
D O I
10.1373/clinchem.2010.152264
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: If liquid-chromatography-multiple-reaction-monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed amultiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS: We used Peptide Atlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS: We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 x immunoassay - 36.6; S-x ' y = 10.3 for apoA-I and LC-MRM/MS = 1.21 x immunoassay + 7.0; S-x ' y = 7.9 for apoB). CONCLUSIONS: Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:1804 / 1813
页数:10
相关论文
共 36 条
[1]   Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass Spectrometry [J].
Abbatiello, Susan E. ;
Mani, D. R. ;
Keshishian, Hasmik ;
Carr, Steven A. .
CLINICAL CHEMISTRY, 2010, 56 (02) :291-305
[2]   Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma [J].
Addona, Terri A. ;
Abbatiello, Susan E. ;
Schilling, Birgit ;
Skates, Steven J. ;
Mani, D. R. ;
Bunk, David M. ;
Spiegelman, Clifford H. ;
Zimmerman, Lisa J. ;
Ham, Amy-Joan L. ;
Keshishian, Hasmik ;
Hall, Steven C. ;
Allen, Simon ;
Blackman, Ronald K. ;
Borchers, Christoph H. ;
Buck, Charles ;
Cardasis, Helene L. ;
Cusack, Michael P. ;
Dodder, Nathan G. ;
Gibson, Bradford W. ;
Held, Jason M. ;
Hiltke, Tara ;
Jackson, Angela ;
Johansen, Eric B. ;
Kinsinger, Christopher R. ;
Li, Jing ;
Mesri, Mehdi ;
Neubert, Thomas A. ;
Niles, Richard K. ;
Pulsipher, Trenton C. ;
Ransohoff, David ;
Rodriguez, Henry ;
Rudnick, Paul A. ;
Smith, Derek ;
Tabb, David L. ;
Tegeler, Tony J. ;
Variyath, Asokan M. ;
Vega-Montoto, Lorenzo J. ;
Wahlander, Asa ;
Waldemarson, Sofia ;
Wang, Mu ;
Whiteaker, Jeffrey R. ;
Zhao, Lei ;
Anderson, N. Leigh ;
Fisher, Susan J. ;
Liebler, Daniel C. ;
Paulovich, Amanda G. ;
Regnier, Fred E. ;
Tempst, Paul ;
Carr, Steven A. .
NATURE BIOTECHNOLOGY, 2009, 27 (07) :633-U85
[3]   A Human Proteome Detection and Quantitation Project [J].
Anderson, N. Leigh ;
Anderson, Norman G. ;
Pearson, Terry W. ;
Borchers, Christoph H. ;
Paulovich, Amanda G. ;
Patterson, Scott D. ;
Gillette, Michael ;
Aebersold, Ruedi ;
Carr, Steven A. .
MOLECULAR & CELLULAR PROTEOMICS, 2009, 8 (05) :883-886
[4]   Mass spectrometric quantitation of peptides and proteins using stable isotope standards and capture by anti-peptide antibodies (SISCAPA) [J].
Anderson, NL ;
Anderson, NG ;
Haines, LR ;
Hardie, DB ;
Olafson, RW ;
Pearson, TW .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (02) :235-244
[5]  
Barr JR, 1996, CLIN CHEM, V42, P1676
[6]   Antiinflammatory properties of HDL [J].
Barter, PJ ;
Nicholls, S ;
Rye, KA ;
Anantharamaiah, GM ;
Navab, M ;
Fogelman, AM .
CIRCULATION RESEARCH, 2004, 95 (08) :764-772
[7]   LC-MS/MS quantification of Zn-α2 glycoprotein:: A potential serum biomarker for prostate cancer [J].
Bondar, Olga P. ;
Barnidge, David R. ;
Klee, Eric W. ;
Davis, Brian J. ;
Klee, George G. .
CLINICAL CHEMISTRY, 2007, 53 (04) :673-678
[8]   Isotope dilution strategies for absolute quantitative proteomics [J].
Brun, Virginie ;
Masselon, Christophe ;
Garin, Jerome ;
Dupuis, Alain .
JOURNAL OF PROTEOMICS, 2009, 72 (05) :740-749
[9]   Protein Quantitation through Targeted Mass Spectrometry: The Way Out of Biomarker Purgatory? [J].
Carr, Steven A. ;
Anderson, Leigh .
CLINICAL CHEMISTRY, 2008, 54 (11) :1749-1752
[10]   Apolipoprotein B and Cardiovascular Disease Risk: Position Statement from the AACC Lipoproteins and Vascular Diseases Division Working Group on Best Practices [J].
Contois, John H. ;
McConnel, Joseph P. ;
Sethi, Amar A. ;
Csako, Gyorgy ;
Devaraj, Sridevi ;
Hoefner, Daniel M. ;
Warnick, Russell .
CLINICAL CHEMISTRY, 2009, 55 (03) :407-419