Pulmonary effects of indoor- and outdoor-generated particles in children with asthma

被引:168
作者
Koenig, JQ
Mar, TF
Allen, RW
Jansen, K
Lumley, T
Sullivan, JH
Trenga, CA
Larson, TV
Liu, LJS
机构
[1] Univ Washington, Dept Environm Hlth & Occupat Sci, Seattle, WA 98195 USA
[2] Univ Washington, Dept Biostat, Seattle, WA 98195 USA
[3] Univ Washington, Dept Civil & Environm Engn, Seattle, WA 98195 USA
关键词
ambient air pollution; asthma; exhaled nitric oxide; infiltration; PM2.5;
D O I
10.1289/ehp.7511
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Most particulate matter (PM) health effects studies use outdoor (ambient) PM as a surrogate for personal exposure. However, people spend most of their time indoors exposed to a combination of indoor-generated particles and ambient particles that have infiltrated. Thus, it is important to investigate the differential health effects of indoor- and ambient-generated particles. We combined our recently adapted recursive model and a predictive model for estimating infiltration efficiency to separate personal exposure (L) to PM2.5 (PM with aerodynamic diameter <= 2.5 pm) into its indoor-generated (E-ig) and ambient-generated (E-ag) components for 19 children with asthma. We then compared E-ig and E-ag to changes in exhaled nitric oxide (eNO), a marker of airway inflammation. Based on the recursive model with a sample size of eight children, E-ag was marginally associated with increases in eNO [5.6 ppb per 10-mu g/m(3) increase in PM2.5; 95% confidence interval (CI), -0.6 to 11.9; p = 0.08]. E-ig was not associated with eNO (-0.19 ppb change per 10 mu g/m(3)). Our predictive model allowed us to estimate E-ag and E-ig for all 19 children. For those combined estimates, only E-ag was significantly associated with an increase in eNO (E-ag: 5.0 ppb per 10-mu g/m(3) increase in PM2.5; 95% CI, 0.3 to 9.7; p = 0.04; E-ig: 3.3 ppb per 10-mu g/m(3) increase in PM2.5; 95% CI, -1.1 to 7.7; p = 0.15). Effects were seen only in children who were not using corticosteroid therapy. We conclude that the ambient-generated component of PM2.5 exposure is consistently associated with increases in eNO, and the indoor-generated component is less strongly associated with eNO.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 39 条
[1]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[2]   Association between air pollution exposure and exhaled nitric oxide in an elderly population [J].
Adamkiewicz, G ;
Ebelt, S ;
Syring, M ;
Slater, J ;
Speizer, FE ;
Schwartz, J ;
Suh, H ;
Gold, DR .
THORAX, 2004, 59 (03) :204-209
[3]   Use of real-time light scattering data to estimate the contribution of infiltrated and indoor-generated particles to indoor air [J].
Allen, R ;
Larson, T ;
Sheppard, L ;
Wallace, L ;
Liu, LJS .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (16) :3484-3492
[4]   Estimated hourly personal exposures to ambient and nonambient particulate matter among sensitive populations in Seattle, Washington [J].
Allen, R ;
Wallace, L ;
Larson, T ;
Sheppard, L ;
Liu, LJS .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (09) :1197-1211
[5]  
[Anonymous], 1995, AM J RESP CRIT CARE, V152, P1107
[6]  
Anuszewski J, 1998, J EXPO ANAL ENV EPID, V8, P483
[7]   Air pollution and life expectancy: is there a relation? [J].
Brunekreef, B .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 54 (11) :781-784
[8]  
Dal Negro R, 2003, ALLERGY, V58, P1018
[9]   Symptoms in pediatric asthmatics and air pollution: Differences in effects by symptom severity, anti-inflammatory medication use and particulate averaging time [J].
Delfino, RJ ;
Zeiger, RS ;
Seltzer, JM ;
Street, DH .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1998, 106 (11) :751-761
[10]   Association of asthma symptoms with peak particulate air pollution and effect modification by anti-inflammatory medication use [J].
Delfino, RJ ;
Zeiger, RS ;
Seltzer, JM ;
Street, DH ;
McLaren, CE .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 (10) :A607-A617