Can optimization of pacing settings compensate for a non-optimal left ventricular pacing site?

被引:45
作者
Bogaard, Margot D. [1 ]
Doevendans, Pieter A. [1 ]
Leenders, Geert E. [1 ]
Loh, Peter [1 ]
Hauer, Richard N. W. [1 ]
van Wessel, Harry [1 ]
Meine, Mathias [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CX Utrecht, Netherlands
来源
EUROPACE | 2010年 / 12卷 / 09期
关键词
Cardiac resynchronization therapy; Interventricular delay; Atrioventricular delay; Left ventricular lead site; Optimization; dP/dt(max); CARDIAC-RESYNCHRONIZATION THERAPY; HEART-FAILURE; LEAD POSITION; INTERVENTRICULAR DELAY; SCAR TISSUE; DYSSYNCHRONY; DEFIBRILLATOR; STIMULATION; CONDUCTION; EVALUATE;
D O I
10.1093/europace/euq167
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Optimal left ventricular (LV) lead position improves the response to cardiac resynchronization therapy (CRT). However, in some patients it is not possible to position the LV lead at an optimal pacing site. The aim of this study was to determine whether optimization of the pacing settings atrioventricular delay (AVD) and interventricular delay (VVD) can compensate for a non-optimal LV pacing site. In 16 patients with heart failure [New York Heart Association class III (13) or IV (3), median QRS duration of 172 ms and median LV ejection fraction of 20%] the acute haemodynamic effect of biventricular pacing was assessed at >= 2 pacing sites by the increase in maximum rate of LV pressure rise (%dP/dt(max)). At each site the AVD and VVD were optimized. Biventricular pacing with nominal settings at a non-optimal LV pacing site improved dP/dt(max) by 12.8% (-0.5 to 23.2%). This could be further improved by 6.5 percentage points (1.2-13.9) by optimization of pacing settings (P = 0.001) and by 9.9 percentage points (3.7-13.3, P = 0.004) by optimization of pacing site. Optimization of the LV pacing site and pacing settings together improved %dP/dt(max) by 16.2 per cent points (10.0-21.8, P < 0.001). Optimization of the AVD and VVD can partly compensate for a non-optimal LV pacing site. However, a combination of an optimal LV pacing site and optimized pacing settings gives the best acute haemodynamic response.
引用
收藏
页码:1262 / 1269
页数:8
相关论文
共 33 条
[11]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[12]   Septal rebound stretch reflects the functional substrate to cardiac resynchronization therapy and predicts volumetric and neurohormonal response [J].
De Boeck, Bart W. L. ;
Teske, Arco J. ;
Meine, Mathias ;
Leenders, Geert E. ;
Cramer, Maarten J. ;
Prinzen, Frits W. ;
Doevendans, Pieter A. .
EUROPEAN JOURNAL OF HEART FAILURE, 2009, 11 (09) :863-871
[13]   Stroke work or systolic dP/dtmax to evaluate acute response to cardiac resynchronization therapy: are they interchangeable? [J].
de Roest, Gerjan ;
Knaapen, Paul ;
Gotte, Marco ;
Hendriks, Thijs ;
Allaart, Cor ;
de Cock, Carel ;
van Rossum, Albert .
EUROPEAN JOURNAL OF HEART FAILURE, 2009, 11 (07) :706-708
[14]   Epicardial left ventricular lead placement for cardiac resynchronization therapy: Optimal pace site selection with pressure-volume loops [J].
Dekker, ALAJ ;
Phelps, B ;
Dijkman, B ;
van Der Nagel, T ;
van Der Veen, FH ;
Geskes, GG ;
Maessen, JG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06) :1641-1647
[15]   Pressure-volume loop analysis during implantation of biventricular pacemaker/cardiac resynchronization therapy device to optimize right and left ventricular pacing sites [J].
Delnoy, Peter Paul H. M. ;
Ottervanger, Jan Paul ;
Luttikhuis, Henk Oude ;
Vos, Dick H. S. ;
Elvan, Arif ;
Ramdat Misier, Anand R. ;
Beukema, Willem P. ;
Steendijk, Paul ;
van Hemel, Norbert M. .
EUROPEAN HEART JOURNAL, 2009, 30 (07) :797-804
[16]   Comparison of stimulation sites within left ventricular veins on the acute hemodynamic effects of cardiac resynchronization therapy [J].
Gold, MR ;
Auricchio, A ;
Hummel, JD ;
Giudici, MC ;
Ding, J ;
Tockman, B ;
Spinelli, J .
HEART RHYTHM, 2005, 2 (04) :376-381
[17]   Electrocardiographic imaging of cardiac resynchronization therapy in heart failure: Observation of variable electrophysiologic responses [J].
Jia, P ;
Ramanathan, C ;
Ghanem, RN ;
Ryu, K ;
Varma, N ;
Rudy, Y .
HEART RHYTHM, 2006, 3 (03) :296-310
[18]   Non-contact left ventricular endocardial mapping in cardiac resynchronisation therapy [J].
Lambiase, PD ;
Rinaldi, A ;
Hauck, J ;
Mobb, M ;
Elliott, D ;
Mohammad, S ;
Gill, JS ;
Bucknall, CA .
HEART, 2004, 90 (01) :44-51
[19]   The interaction of interventricular pacing intervals and left ventricular lead position during temporary biventricular pacing evaluated by tissue Doppler imaging [J].
Lane, R. E. ;
Chow, A. W. C. ;
Mayet, J. ;
Francis, D. P. ;
Peters, N. S. ;
Schilling, R. J. ;
Davies, D. W. .
HEART, 2007, 93 (11) :1426-1432
[20]   Tissue synchronization imaging and optimal left ventricular pacing site in cardiac resynchronization therapy [J].
Murphy, Ross T. ;
Sigurdsson, Gardar ;
Mulamalla, Sumanth ;
Agler, Deborah ;
Popovic, Zoran B. ;
Starling, Randall C. ;
Wilkoff, Bruce L. ;
Thomas, James D. ;
Grimm, Richard A. .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (11) :1615-1621