Electrochemical glucose biosensors

被引:2789
作者
Wang, Joseph [1 ,2 ,3 ]
机构
[1] Arizona State Univ, Biodesign Inst, Ctr Bioelect & Biosensors, Dept Chem Engn, Tempe, AZ 85287 USA
[2] Arizona State Univ, Biodesign Inst, Ctr Bioelect & Biosensors, Dept Chem, Tempe, AZ 85287 USA
[3] Arizona State Univ, Biodesign Inst, Ctr Bioelect & Biosensors, Dept Biochem, Tempe, AZ 85287 USA
关键词
D O I
10.1021/cr068123a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical glucose biosensors account for about 85% of the entire biosensor market. Such huge market size makes diabetes a model disease for developing new biosensing concepts. The first generation of glucose biosensors make use of the natural oxygen cosubstrate and generation and detection of hydrogen peroxide. The biocatalytic reaction involves reduction of the flavin group in the enzyme by reaction with glucose to give the reduced form of the enzyme. The first generation of glucose biosensors needed the reduction of electroactive interferences by employing a permselective coating that minimizes the access of constituents toward the electrode surface. The second generation of glucose biosensors saw improvements, such as the replacing of oxygen with a nonphysiological electron acceptor capable of shuttling electrons from the redox center of the enzyme between the GOx active site. The next generation will involve the elimination of the mediator and the development of a reagentless glucose biosensor with a low operating potential, close to that of the redox potential of the enzyme.
引用
收藏
页码:814 / 825
页数:12
相关论文
共 107 条
[1]   AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE [J].
ALBERY, WJ ;
BARTLETT, PN ;
CRASTON, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :223-235
[2]   CLINICAL CONTROL OF DIABETES BY ARTIFICIAL PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W ;
SCHIPPER, H ;
GANDER, R .
DIABETES, 1974, 23 (05) :397-404
[3]  
[Anonymous], **NON-TRADITIONAL**, DOI DOI 10.1089/15209150050214087
[4]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[5]   Modification of glucose oxidase by the covalent attachment of a tetrathiafulvalene derivative [J].
Bartlett, PN ;
Booth, S ;
Caruana, DJ ;
Kilburn, JD ;
Santamaria, C .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :734-742
[6]   A MICROELECTROCHEMICAL ENZYME TRANSISTOR RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1552-1559
[7]   Enzyme-coated carbon nanotubes as single-molecule biosensors [J].
Besteman, K ;
Lee, JO ;
Wiertz, FGM ;
Heering, HA ;
Dekker, C .
NANO LETTERS, 2003, 3 (06) :727-730
[8]   Recording of subcutaneous glucose dynamics by a viscometric affinity sensor [J].
Beyer, U ;
Schäfer, D ;
Thomas, A ;
Aulich, H ;
Haueter, U ;
Reihl, B ;
Ehwald, R .
DIABETOLOGIA, 2001, 44 (04) :416-423
[9]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[10]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671