Electrochemical glucose biosensors

被引:2789
作者
Wang, Joseph [1 ,2 ,3 ]
机构
[1] Arizona State Univ, Biodesign Inst, Ctr Bioelect & Biosensors, Dept Chem Engn, Tempe, AZ 85287 USA
[2] Arizona State Univ, Biodesign Inst, Ctr Bioelect & Biosensors, Dept Chem, Tempe, AZ 85287 USA
[3] Arizona State Univ, Biodesign Inst, Ctr Bioelect & Biosensors, Dept Biochem, Tempe, AZ 85287 USA
关键词
D O I
10.1021/cr068123a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical glucose biosensors account for about 85% of the entire biosensor market. Such huge market size makes diabetes a model disease for developing new biosensing concepts. The first generation of glucose biosensors make use of the natural oxygen cosubstrate and generation and detection of hydrogen peroxide. The biocatalytic reaction involves reduction of the flavin group in the enzyme by reaction with glucose to give the reduced form of the enzyme. The first generation of glucose biosensors needed the reduction of electroactive interferences by employing a permselective coating that minimizes the access of constituents toward the electrode surface. The second generation of glucose biosensors saw improvements, such as the replacing of oxygen with a nonphysiological electron acceptor capable of shuttling electrons from the redox center of the enzyme between the GOx active site. The next generation will involve the elimination of the mediator and the development of a reagentless glucose biosensor with a low operating potential, close to that of the redox potential of the enzyme.
引用
收藏
页码:814 / 825
页数:12
相关论文
共 107 条
[71]   DEVELOPMENT AND EVALUATION OF GLUCOSE MICROSENSORS BASED ON ELECTROCHEMICAL CODEPOSITION OF RUTHENIUM AND GLUCOSE-OXIDASE ONTO CARBON-FIBER MICROELECTRODES [J].
SAKSLUND, H ;
WANG, J ;
LU, F ;
HAMMERICH, O .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :149-155
[72]   ELECTROPOLYMERIZED 1,2-DIAMINOBENZENE AS A MEANS TO PREVENT INTERFERENCES AND FOULING AND TO STABILIZE IMMOBILIZED ENZYME IN ELECTROCHEMICAL BIOSENSORS [J].
SASSO, SV ;
PIERCE, RJ ;
WALLA, R ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1111-1117
[73]   ELECTROCHEMICAL MEASUREMENT OF GLUCOSE USING VARIOUS ELECTRON-ACCEPTORS [J].
SCHLAPFER, P ;
MINDT, W ;
RACINE, P .
CLINICA CHIMICA ACTA, 1974, 57 (03) :283-289
[74]   Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin [J].
Schmidtke, DW ;
Freeland, AC ;
Heller, A ;
Bonnecaze, RT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (01) :294-299
[75]  
SHICHIRI M, 1982, LANCET, V2, P1129
[76]   Nitric oxide-releasing sol-gel particle/polyurethane glucose biosensors [J].
Shin, JH ;
Marxer, SM ;
Schoenfisch, MH .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4543-4549
[77]   COVALENT ENZYME COUPLING ON CELLULOSE-ACETATE MEMBRANES FOR GLUCOSE SENSOR DEVELOPMENT [J].
STERNBERG, R ;
BINDRA, DS ;
WILSON, GS ;
THEVENOT, DR .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2781-2786
[78]  
Tierney MJ, 2000, ELECTROANAL, V12, P666, DOI 10.1002/1521-4109(200005)12:9<666::AID-ELAN666>3.3.CO
[79]  
2-3
[80]  
Turner APF, 1999, CLIN CHEM, V45, P1596