Detection of formaldehyde vapor using mercaptophenol-coated piezoresistive cantilevers

被引:39
作者
Seo, Hyejung [1 ]
Jung, Sunghye [1 ]
Jeon, Sangmin [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Chem Engn, Pohang, South Korea
关键词
formaldehyde; mercaptophenol; piezoresistive cantilever;
D O I
10.1016/j.snb.2007.04.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Piezoresistive cantilevers coated with mercaptophenol self-assembled monolayers were used to detect formaldehyde vapor at room temperature. The three isomers of mercaptophenol, namely 2-, 3-, and 4-mercaptophenol, were tested as probe molecules. The 3 -mercaptophenol -coated cantilever showed the largest deflection due to high reactivity between formaldehyde and 3-mercaptophenol. When the 3 -merc aptophenol -coated cantilever was exposed to interferents such as benzene, toluene, p-xylene, water, or ethanol, the deflection direction of the cantilever was the opposite of that induced by the chemical reaction with formaldehyde, indicating that 3-mercaptophenot is very specific to formaldehyde. The detection limit of the 3-mercaptophenol -coated cantilever was determined to be better than 0.01 ppm. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:522 / 526
页数:5
相关论文
共 28 条
[1]   Surface stress in the self-assembly of alkanethiols on gold [J].
Berger, R ;
Delamarche, E ;
Lang, HP ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Guntherodt, HJ .
SCIENCE, 1997, 276 (5321) :2021-2024
[2]   Environmental sensors based on micromachined cantilevers with integrated read-out [J].
Boisen, A ;
Thaysen, J ;
Jensenius, H ;
Hansen, O .
ULTRAMICROSCOPY, 2000, 82 (1-4) :11-16
[3]   A piezoelectric method for monitoring formaldehyde induced crosslink formation between poly-lysine and poly-deoxyguanosine [J].
Bunde, RL ;
Jarvi, EJ ;
Rosentreter, JJ .
TALANTA, 2000, 51 (01) :159-171
[4]   NiO thin-film formaldehyde gas sensor [J].
Dirksen, JA ;
Duval, K ;
Ring, TA .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (02) :106-115
[5]  
FESSENDEN RJ, 1998, ORGANIC CHEM, P504
[6]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[7]   DETERMINATION OF NANOGRAM AMOUNTS OF CARBONYLS AS 2,4-DINITROPHENYLHYDRAZONES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FUNG, K ;
GROSJEAN, D .
ANALYTICAL CHEMISTRY, 1981, 53 (02) :168-171
[8]   OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR [J].
GIMZEWSKI, JK ;
GERBER, C ;
MEYER, E ;
SCHLITTLER, RR .
CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) :589-594
[9]   SOME NEW ASPECTS OF A HPLC-METHOD FOR THE DETERMINATION OF TRACES OF FORMALDEHYDE IN AIR [J].
GROMPING, A ;
CAMMANN, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (07) :796-801
[10]   DETERMINATION OF FORMALDEHYDE WITH AN ENZYME-COATED PIEZOELECTRIC CRYSTAL DETECTOR [J].
GUILBAULT, GG .
ANALYTICAL CHEMISTRY, 1983, 55 (11) :1682-1684