Electrocatalytic activity of carbon spheres towards NADH oxidation at low overpotential and its applications in biosensors and biofuel cells

被引:42
作者
Gao, Feng [1 ]
Guo, Xinying [1 ]
Yin, Jun [1 ]
Zhao, Dan [1 ]
Li, Maoguo [1 ]
Wang, Lun [1 ]
机构
[1] Anhui Normal Univ, Key Lab Chemo Biosensing, Anhui Key Lab Funct Mol Solids, Coll Chem & Mat Sci, Wuhu 241000, Peoples R China
关键词
NICOTINAMIDE ADENINE-DINUCLEOTIDE; DIRECT ELECTRON-TRANSFER; GRAPHITE-ELECTRODES; AMPEROMETRIC BIOSENSOR; CATALYTIC-OXIDATION; BILIRUBIN OXIDASE; ELECTROCHEMICAL OXIDATION; LACTATE-DEHYDROGENASE; ADSORPTION; BINDERLESS;
D O I
10.1039/c1ra00444a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The excellent electrocatalytic activity of a micro-structured carbon material, carbon hollow spheres (CS), to the oxidation of dihydronicotinamide adenine dinucleotide (NADH) is demonstrated here. Compared to conventional bare glassy carbon electrodes, a substantial decrease by 450 mV in the overpotential of NADH electrooxidation was observed using CS coatings, with oxidation starting at ca. -0.10 V (vs. Ag/AgCl, pH 7.0). The CS-coated glassy carbon electrode (CS/GC) thus allows highly sensitive and direct amperometric detection of NADH at lower potential, ranging from 0.20 to 100 mu M with a high sensitivity of 7.3 +/- 0.2 nA mu M-1 (i.e., 103.3 +/- 2.8 nA mu M-1 cm(-2)), low detection limit of 0.08 +/- 0.03 mu M, and minimization of surface fouling. With lactate dehydrogenase (LDH) as a model, a lactate biosensor with the LDH-CS/GC electrode was constructed and the biosensor shows rapid and highly sensitive amperometric response to lactate ranging from 0.5 to 12 mM with a detection limit of 3.7 +/- 0.2 mu M, a sensitivity of 4.1 +/- 0.2 nA mu M-1 (i.e., 57.9 +/- 2.8 nA mu M-1 cm(-2)), good reproducibility and excellent stability. Furthermore, the promoted direct electron transfer (DET) of bilirubin oxidase (BOD) on CS/GC electrode was investigated, and thus a membrane-less lactate/oxygen biofuel cell was assembled by using LDH-CS/GC as bioanode for lactate oxidation and BOD-CS/GC electrode for oxygen reduction, with a high open-circuit potential of 0.60 V. Such ability of CS to decrease the NADH oxidation overpotential and promote DET of blue-copper oxidases suggests great promise for dehydrogenase-based amperometric biosensors and biofuel cells.
引用
收藏
页码:1301 / 1309
页数:9
相关论文
共 82 条
[1]  
Antiochia R, 2002, ELECTROANAL, V14, P1256, DOI 10.1002/1521-4109(200210)14:18<1256::AID-ELAN1256>3.0.CO
[2]  
2-N
[3]   Edge plane pyrolytic graphite electrodes in electroanalysis: An overview [J].
Banks, CE ;
Compton, RG .
ANALYTICAL SCIENCES, 2005, 21 (11) :1263-1268
[4]   Exploring the electrocatalytic sites of carbon nanotubes for NADH detection: an edge plane pyrolytic graphite electrode study [J].
Banks, CE ;
Compton, RG .
ANALYST, 2005, 130 (09) :1232-1239
[5]   Oxidation of beta-nicotinamide adenine dinucleotide (NADH) at poly(aniline)-coated electrodes [J].
Bartlett, PN ;
Birkin, PR ;
Wallace, ENK .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1997, 93 (10) :1951-1960
[6]   Enzymatic biofuel cells for Implantable and microscale devices [J].
Barton, SC ;
Gallaway, J ;
Atanassov, P .
CHEMICAL REVIEWS, 2004, 104 (10) :4867-4886
[7]  
Bernadette F. Y., 1987, ANAL CHEM, V59, P2111
[8]   The characterization of activated carbons with oxygen and nitrogen surface groups [J].
Biniak, S ;
Szymanski, G ;
Siedlewski, J ;
Swiatkowski, A .
CARBON, 1997, 35 (12) :1799-1810
[9]   AN INVESTIGATION OF CARBON-FIBER SURFACE-CHEMISTRY AND REACTIVITY BASED ON XPS AND SURFACE FREE-ENERGY [J].
BRADLEY, RH ;
LING, X ;
SUTHERLAND, I .
CARBON, 1993, 31 (07) :1115-1120
[10]   Amperometric biosensor for ethanol based on immobilization of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode [J].
Cai, CX ;
Xue, KH ;
Zhou, YM ;
Yang, H .
TALANTA, 1997, 44 (03) :339-347