A sensitive immunosensor using colloidal gold as electrochemical label

被引:38
作者
Chen, Zhao-Peng
Peng, Zhao-Feng
Zhang, Peng
Jin, Xue-Fang
Jiang, Jian-Hui
Zhang, Xiao-Bing
Shen, Guo-Li
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Peoples R China
[2] Hunan Normal Univ, Minist Educ, Chem & Chem Engn Coll, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Peoples R China
[3] Chinese Acad Sci, Yantai Inst Coastal Zone Res Sustainable Dev, Dept Environm Chem, Yantai 264003, Peoples R China
基金
中国国家自然科学基金;
关键词
immunosensor; colloidal gold; electrochemical label; adsorptive voltammetry;
D O I
10.1016/j.talanta.2007.02.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive immunosensor using colloidal gold as electrochemical label is described. In this method, the capture protein was first immobilized on a carbon paste electrode surface through passive adsorption to bind quantitatively with corresponding antigen and colloidal gold labeled antibody to perform a sandwich assay. To detect the amount of the colloidal gold captured on the electrode surface, the colloid was first oxidized electrochemically to produce AuCl4- ions which were adsorbed strongly on the electrode surface. Adsorptive voltammetry was then employed for the determination of the adsorbed AuCl4- ions. A linear relationship between reduction wave peak cur-rent and the antigen concentration (human IgG) from 10 to 500 ng/ml is obtained with a detection limit of 4.0 ng/ml. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1800 / 1804
页数:5
相关论文
共 16 条
[1]   Gold nanoparticle-based quantitative electrochemical detection of amplified human cytomegalovirus DNA using disposable microband electrodes [J].
Authier, L ;
Grossiord, C ;
Brossier, P ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4450-4456
[2]   An electrochemical metalloimmunoassay based on a colloidal gold label [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5521-5528
[3]  
FAULK WP, 1971, IMMUNOCHEMISTRY, V8, P1081
[4]  
Gonzalez Garcia M. B., 1995, Bioelectrochemistry and Bioenergetics, V38, P389, DOI 10.1016/0302-4598(95)01813-T
[5]   Colloidal gold as an electrochemical label of streptavidin-biotin interaction [J].
González-García, MB ;
Fernández-Sánchez, C ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) :315-321
[6]   PREPARATION AND CHARACTERIZATION OF AU COLLOID MONOLAYERS [J].
GRABAR, KC ;
FREEMAN, RG ;
HOMMER, MB ;
NATAN, MJ .
ANALYTICAL CHEMISTRY, 1995, 67 (04) :735-743
[7]   The distance-dependence of colloidal Au-amplified surface plasmon resonance [J].
He, L ;
Smith, EA ;
Natan, MJ ;
Keating, CD .
JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (30) :10973-10980
[8]   Colloidal Au-enhanced surface plasmon resonance for ultrasensitive detection of DNA hybridization [J].
He, L ;
Musick, MD ;
Nicewarner, SR ;
Salinas, FG ;
Benkovic, SJ ;
Natan, MJ ;
Keating, CD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (38) :9071-9077
[9]   COLLOIDAL GOLD GRANULES AS MARKERS FOR CELL-SURFACE RECEPTORS IN SCANNING ELECTRON-MICROSCOPE [J].
HORISBERGER, M ;
ROSSET, J ;
BAUER, H .
EXPERIENTIA, 1975, 31 (10) :1147-1149
[10]  
IMDADULLAH T, 1993, ANAL CHEM, V65, P421