The effect of an interspinous process implant on facet loading during extension

被引:171
作者
Wiseman, CM
Lindsey, DP
Fredrick, AD
Yerby, SA
机构
[1] St Francis Med Technol Inc, Alameda, CA 94501 USA
[2] San Francisco Orthopaed Residency Programs, San Francisco, CA USA
[3] VA Rehab R&D Ctr, Palo Alto, CA USA
关键词
facet joint; neurogenic intermittent claudication; lumbar; back pain; interspinous process decompression;
D O I
10.1097/01.brs.0000158876.51771.f8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Facet loading parameters of lumbar cadaver spines were measured during extension before and after placement of an interspinous process implant. Objective. The study was undertaken to quantify the influence of an interspinous implant on facet loading at the implanted and adjacent levels during extension. Summary of Background Data. Facet loading is increased during extension and decreased during flexion. Previous studies have demonstrated that interspinous process decompression relieves disc pressure at the implanted level and does not alter disc pressure at the adjacent levels. Facet joints are believed to play a key role in back pain, especially in patients with collapsed discs and increased motion segment mobility resulting in increased facet loading. Methods. Seven cadaver spines (L2 - L5) were loaded to 15 Nm of extension and 700 N compression with and without an interspinous process implant ( X STOP) placed between the L3 - L4 spinous processes. Pressure-sensitive film was placed in the facet joints of the implanted and adjacent levels. After loading, the film was digitally analyzed for peak pressure, average pressure, contact area, and force. These values were compared between the intact and implanted specimens at the adjacent and implanted levels using a paired t test ( P < 0.05). Results. The implant significantly reduced the mean peak pressure, average pressure, contact area, and force at the implanted level. The mean peak pressure, average pressure, contact area, and force at the adjacent levels were not significantly different between the intact and implanted specimens with the exception of contact area at the L2 - L3 level. Conclusions. Interspinous process decompression will unlikely cause adjacent level facet pain or accelerated facet joint degeneration. Furthermore, pain induced from pressure originating in the facets and/or posterior anulus of the lumbar spine may be relieved by interspinous process decompression. Clinical results from patients with a component of lower back pain suggest that this is a valid conclusion.
引用
收藏
页码:903 / 907
页数:5
相关论文
共 27 条
[1]   BIOMECHANICAL EVALUATION OF LUMBAR SPINAL STABILITY AFTER GRADED FACETECTOMIES [J].
ABUMI, K ;
PANJABI, MM ;
KRAMER, KM ;
DURANCEAU, J ;
OXLAND, T ;
CRISCO, JJ .
SPINE, 1990, 15 (11) :1142-1147
[2]   THE EFFECT OF POSTURE ON THE ROLE OF THE APOPHYSEAL JOINTS IN RESISTING INTERVERTEBRAL COMPRESSIVE FORCES [J].
ADAMS, MA ;
HUTTON, WC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1980, 62 (03) :358-362
[3]   THE RELEVANCE OF TORSION TO THE MECHANICAL DERANGEMENT OF THE LUMBAR SPINE [J].
ADAMS, MA ;
HUTTON, WC .
SPINE, 1981, 6 (03) :241-248
[4]   THE EFFECTS OF CONTROLLED MECHANICAL LOADING ON GROUP-II, GROUP-III, AND GROUP-IV AFFERENT UNITS FROM THE LUMBAR FACET JOINT AND SURROUNDING TISSUE - AN INVITRO STUDY [J].
AVRAMOV, AI ;
CAVANAUGH, JM ;
OZAKTAY, CA ;
GETCHELL, TV ;
KING, AI .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (10) :1464-1471
[5]   POSTEROLATERAL LUMBAR FUSION - OUTCOME OF 71 CONSECUTIVE OPERATIONS AFTER 4 (2-7) YEARS [J].
AXELSSON, P ;
JOHNSSON, R ;
STROMQVIST, B ;
ARVIDSSON, M ;
HERRLIN, K .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (03) :309-314
[6]   The lumbar zygapophyseal (facet) joints: A role in the pathogenesis of spinal pain syndromes and degenerative spondylolisthesis [J].
Berven, S ;
Tay, BBK ;
Colman, W ;
Hu, SS .
SEMINARS IN NEUROLOGY, 2002, 22 (02) :187-195
[7]   Lumbar facet pain: Biomechanics, neuroanatomy and neurophysiology [J].
Cavanaugh, JM ;
Ozaktay, AC ;
Yamashita, HT ;
King, AI .
JOURNAL OF BIOMECHANICS, 1996, 29 (09) :1117-1129
[8]   Load-Sharing Between Anterior and Posterior Elements in a Lumbar Motion Segment Implanted With an Artificial Disc [J].
Dooris, Andrew P. ;
Goel, Vijay K. ;
Grosland, Nicole M. ;
Gilbertson, Lars G. ;
Wilder, David G. .
SPINE, 2001, 26 (06) :E122-E129
[9]   Low back pain and the zygapophysial (facet) joints [J].
Dreyer, SJ ;
Dreyfuss, PH .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (03) :290-300
[10]   EXPERIMENTAL-VERIFICATION OF FACET LOAD TRANSMISSION BY DIRECT MEASUREMENT OF FACET LAMINA CONTACT PRESSURE [J].
ELBOHY, AA ;
YANG, KH ;
KING, AI .
JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) :931-&