Left Ventricular Mass Regression One Year After Transcatheter Aortic Valve Implantation

被引:34
作者
Tzikas, Apostolos [1 ]
Geleijnse, Marcel L. [1 ]
Van Mieghem, Nicolas M. [1 ]
Schultz, Carl J. [1 ]
Nuis, Rutger-Jan [1 ]
van Dalen, Bas M. [1 ]
Sarno, Giovanna [1 ]
van Domburg, Ron T. [1 ]
Serruys, Patrick W. [1 ]
de Jaegere, Peter P. T. [1 ]
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr, NL-3000 CA Rotterdam, Netherlands
关键词
DIASTOLIC FUNCTION; HEART-VALVE; STENOSIS; REPLACEMENT; HYPERTROPHY; REGURGITATION; EXPERIENCE; RECOMMENDATIONS; DYSFUNCTION;
D O I
10.1016/j.athoracsur.2010.09.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Left ventricular (LV) hypertrophy is associated with LV diastolic dysfunction and constitutes a risk factor for cardiac morbidity and mortality. The objective of this study was to investigate the degree of LV mass regression and the changes of LV diastolic function one year after transcatheter aortic valve implantation (TAVI). Methods. Echocardiography was performed at baseline, before discharge, and at one-year follow-up in 63 consecutive patients with severe aortic stenosis who underwent TAVI with the Medtronic CoreValve System (Medtronic Inc, Minneapolis, MN). The LV mass was calculated using the Devereux formula and indexed to body surface area. Results. One-year all-cause mortality was 29%. The LV mass index decreased from 126 +/- 42 g/m(2) at baseline to 110 +/- 30 g/m(2) at one-year follow-up (p < 0.001). Left ventricular ejection fraction and LV diastolic function did not change significantly. Mean transaortic gradient decreased from 47 +/- 19 mm Hg at baseline to 9 +/- 5 mm Hg at discharge and 9 +/- 4 mm Hg at one year (p < 0.001), and was accompanied by significant clinical improvement. More than mild paravalvular aortic regurgitation was found in 24% and 15% of patients at discharge and one-year follow-up, respectively. Conclusions. A significant regression in LV mass was found one year after TAVI. However, regression was incomplete and was not accompanied by an improvement in LV diastolic function.
引用
收藏
页码:685 / 691
页数:7
相关论文
共 26 条
[1]   Immediate and Long-Term Echocardiographic Findings after Transcatheter Aortic Valve Implantation for the Treatment of Aortic Stenosis: The Cribier-Edwards/Edwards-Sapien Valve Experience [J].
Bauer, Fabrice ;
Lemercier, Mathieu ;
Zajarias, Alan ;
Tron, Christophe ;
Eltchaninoff, Helene ;
Cribier, Alain .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (04) :370-376
[2]   New insights into the relationship of left ventricular geometry and left ventricular mass with cardiac function: a population study of hypertensive subjects [J].
Chahal, Navtej S. ;
Lim, Tiong K. ;
Jain, Piyush ;
Chambers, John C. ;
Kooner, Jaspal S. ;
Senior, Roxy .
EUROPEAN HEART JOURNAL, 2010, 31 (05) :588-594
[3]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[4]   Angiotensin-converting enzyme gene polymorphism influences degree of left ventricular hypertrophy and its regression in patients undergoing operation for aortic stenosis [J].
Dellgren, G ;
Eriksson, MJ ;
Blange, I ;
Brodin, LÅ ;
Rådegran, K ;
Sylvén, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (08) :909-913
[5]   Prognostic significance of left ventricular mass change during treatment of hypertension [J].
Devereux, RB ;
Wachtell, K ;
Gerdts, E ;
Boman, K ;
Nieminen, MS ;
Papademetriou, V ;
Rokkedal, J ;
Harris, K ;
Aurup, P ;
Dahlöf, B .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (19) :2350-2356
[6]   ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR HYPERTROPHY - COMPARISON TO NECROPSY FINDINGS [J].
DEVEREUX, RB ;
ALONSO, DR ;
LUTAS, EM ;
GOTTLIEB, GJ ;
CAMPO, E ;
SACHS, I ;
REICHEK, N .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (06) :450-458
[7]   Paradoxical low flow and/or low gradient severe aortic stenosis despite preserved left ventricular ejection fraction: implications for diagnosis and treatment [J].
Dumesnil, Jean G. ;
Pibarot, Philippe ;
Carabello, Blase .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :281-289
[8]   Influence of concentric left ventricular remodeling on early mortality after aortic valve replacement [J].
Duncan, Andra Ibrahim ;
Lowe, Boris S. ;
Garcia, Mario J. ;
Xu, Meng ;
Gillinov, A. Marc ;
Mihaljevic, Tomislav ;
Koch, Colleen G. .
ANNALS OF THORACIC SURGERY, 2008, 85 (06) :2030-2039
[9]   Left ventricular diastolic dysfunction late after aortic valve replacement in patients with aortic stenosis [J].
Gjertsson, P ;
Caidahl, K ;
Bech-Hanssen, O .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (05) :722-727
[10]   Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantation [J].
Gotzmann, Michael ;
Lindstaedt, Michael ;
Bojara, Waldemar ;
Muegge, Andreas ;
Germing, Alfried .
AMERICAN HEART JOURNAL, 2010, 159 (05) :926-932