Electrogram fractionation in murine HL-1 atrial monolayer model

被引:35
作者
Umapathy, Karthikeyan
Masse, Stephane
KoLodziejska, Karohna
Veenhuyzen, George D. [2 ]
Chauhan, Vijay S.
Husain, Mansoor
Farid, Talha
Downar, Eugene
Sevaptsidis, Elias
Nanthakurnar, Kumaraswamy [1 ]
机构
[1] Toronto Gen Hosp, Toby Hull Cardiac Fibrillat Management Lab, Univ Hlth Network, Div Cardiol, Toronto, ON M5G 2C4, Canada
[2] Univ Calgary, Libin Cardiovasc Inst Alberta, Div Cardiovasc Sci, Calgary, AB, Canada
基金
加拿大健康研究院;
关键词
fractionated electrograms; atrial fibrillation; atrial monolayer model; rotors; ablation;
D O I
10.1016/j.hrthm.2008.03.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Complex fractionated atrial electrograms have been suggested as important targets for catheter ablation of atrial fibrillation. The etiology and the mechanism of these signals have not been completely elucidated because of Limitations of interpretation of these signals in relation to simultaneously acquired signals in the neighboring atrial tissue. OBJECTIVE This study sought to study the origin of electrogram fractionation under the conditions of rotor formation and wave fragmentation, using atrial monolayer preparations. METHODS We performed optical mapping of 45 atrial monolayer preparations using a complementary metal oxide semiconductor (CMOS) Brainvision Ultima camera system (SciMedia-Brainvision, Tokyo, Japan). RESULTS We observed stable rotors in 32 of the 45 recordings. The derived bipolar electrograms did not show complex fractionation at the core of the rotor in any of the 32 recordings. We were also able to show that 2 bipolar electrodes placed adjacent to the core of a stable rotor in a zone where there is no wave break will record electrical activity for the majority of the rotors cycle Length. In 13 of the 45 recordings, wave break or wave collision events were present. Of these, 8 of 13 recordings showed complex fractionation. In 19 of the 27, simulation of meandering rotors also showed complex fractionation. CONCLUSION Complex fractionated electrograms can be recorded at sites of migrating rotors and wave break. No fractionation occurs at the core of a stable rotor. Electrograms that span the rotor cycle Length and alternate between 2 bipoles that straddle the core can identify site of a stable rotor.
引用
收藏
页码:1029 / 1035
页数:7
相关论文
共 18 条
[11]   Radiofrequency catheter ablation of chronic atrial fibrillation guided by complex electrograms [J].
Oral, Hakan ;
Chugh, Aman ;
Good, Eric ;
Wimmer, Alan ;
Dey, Sujoya ;
Gadeela, Nitesh ;
Sankaran, Sundar ;
Crawford, Thomas ;
Sarrazin, Jean F. ;
Kuhne, Michael ;
Chalfoun, Nagib ;
Wells, Darryl ;
Frederick, Melissa ;
Fortino, Jackie ;
Benloucif-Moore, Suzanne ;
Jongnarangsin, Krit ;
Pelosi, Frank, Jr. ;
Bogun, Frank ;
Morady, Fred .
CIRCULATION, 2007, 115 (20) :2606-2612
[12]   High-density activation mapping of fractionated electrograms in the atria of patients with paroxysmal atrial fibrillation [J].
Rostock, T ;
Rotter, M ;
Sanders, P ;
Takahashi, Y ;
Jaïs, P ;
Hocini, M ;
Hsu, LF ;
Sacher, F ;
Clémenty, J ;
Haïssaguerre, M .
HEART RHYTHM, 2006, 3 (01) :27-34
[13]   Fibrillating areas isolated within the left atrium after radiofrequency linear catheter ablation [J].
Rostock, Thomas ;
Rotter, Martin ;
Sanders, Prashanthan ;
Jais, Pierre ;
Hocini, Meleze ;
Takahashi, Yoshihide ;
Sacher, Frederic ;
Jonsson, Anders ;
O'Neill, Mark D. ;
Hsu, Li-Fern ;
Clementy, Jacques ;
Haissaguerre, Michel .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (08) :807-812
[14]   Spectral analysis identifies sites of high-frequency activity maintaining atrial fibrillation in humans [J].
Sanders, P ;
Berenfeld, O ;
Hocini, MZ ;
Jaïs, P ;
Vaidyanathan, R ;
Hsu, LF ;
Garrigue, S ;
Takahashi, Y ;
Rotter, M ;
Sacher, F ;
Scavée, C ;
Ploutz-Snyder, R ;
Jalife, J ;
Haïssaguerre, M .
CIRCULATION, 2005, 112 (06) :789-797
[15]   Spatial and temporal stability of the dominant frequency of activation in human atrial fibrillation [J].
Schuessler, Richard B. ;
Kay, Matthew W. ;
Melby, Spencer J. ;
Branham, Barry H. ;
Boineau, John P. ;
Damiano, Ralph J., Jr. .
JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (04) :S7-S12
[16]   Spatiotemporal periodicity during atrial fibrillation in the isolated sheep heart [J].
Skanes, AC ;
Mandapati, R ;
Berenfeld, O ;
Davidenko, JM ;
Jalife, J .
CIRCULATION, 1998, 98 (12) :1236-1248
[17]   Effects of stepwise ablation of chronic atrial fibrillation on atrial electrical and mechanical properties [J].
Takahashi, Yoshihide ;
O'Neill, Mark D. ;
Hocini, Meleze ;
Reant, Patricia ;
Jonsson, Anders ;
Jais, Pierre ;
Sanders, Prashanthan ;
Rostock, Thomas ;
Rotter, Martin ;
Sacher, Frederic ;
Laffite, Stephane ;
Roudaut, Raymond ;
Clementy, Jacques ;
Haissaguerre, Michel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (12) :1306-1314
[18]   A prospective, multicenter evaluation of ablating complex fractionated electrograms (CFEs) during atrial fibrillation (AF) identified by an automated mapping algorithm: Acute effects on AF and efficacy as an adjuvant strategy [J].
Verma, Atut ;
Novak, Paul ;
Macle, Laurent ;
Whaley, Bonnie ;
Beardsall, Marianne ;
Wulffhart, Zaev ;
Khaykin, Yaariv .
HEART RHYTHM, 2008, 5 (02) :198-205