Analysis of luminescent samples using subtracted shifted Raman spectroscopy

被引:67
作者
Bell, SEJ [1 ]
Bourguignon, ESO [1 ]
Dennis, A [1 ]
机构
[1] Queens Univ Belfast, Sch Chem, Belfast BT9 5AG, Antrim, North Ireland
关键词
Raman spectroscopy; resonance Raman spectroscopy; luminescence suppression; background suppression; charge coupled device detectors; shifted excitation; Raman difference;
D O I
10.1039/a802802h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method of obtaining high-quality Raman spectra of luminescent samples was tested using cyclohexane solutions which had been treated with a fluorescent dye. The method involves removing the fixed pattern irregularity found in the spectra taken with CCD detectors by subtracting spectra taken at several different, closely spaced spectrometer positions. It is conceptually similar to SERDS (shifted excitation Raman difference spectroscopy) but has the distinct experimental advantage that it does not require a tunable laser source. The subtracted spectra obtained as the raw data are converted into a more recognisable and conventional form by iterative fitting of appropriate double Lorentzian functions whose peak parameters are then used to 'reconstruct' a conventional representation of the spectrum. Importantly, it is shown that the degree of uncertainty in the resultant 'reconstructed' spectra can be gauged reliably by comparing reconstructed spectra obtained at two different spectrometer shifts (delta and 2 delta), The method was illustrated and validated using a solvent (cyclohexane) the spectrum of which is well known and which contains both regions with complex overlapping bands and regions with isolated bands, Possible sources of error are discussed and it is shown that, provided the degree of uncertainty in the data is correctly characterised, it is completely valid to draw conclusions about the spectra of the sample on the basis of the reconstructed data. The acronym SSRS (subtracted shifted Raman spectroscopy; pronounced scissors) is proposed for this method, to distinguish it from the SERDS technique.
引用
收藏
页码:1729 / 1734
页数:6
相关论文
共 28 条
[1]   RAPID NEAR-INFRARED RAMAN-SPECTROSCOPY OF HUMAN TISSUE WITH A SPECTROGRAPH AND CCD DETECTOR [J].
BARAGA, JJ ;
FELD, MS ;
RAVA, RP .
APPLIED SPECTROSCOPY, 1992, 46 (02) :187-190
[2]   Near-infrared Raman spectrometer systems for human tissue studies [J].
Brennan, JF ;
Wang, Y ;
Dasari, RR ;
Feld, MS .
APPLIED SPECTROSCOPY, 1997, 51 (02) :201-208
[3]  
Chang R.K., 1982, Surface Enhanced Raman Scattering
[4]  
CHASE B, 1996, P 15 INT C RAM SPECT, V1, P1072
[5]   FOURIER-TRANSFORM RAMAN-SPECTROSCOPY [J].
CHASE, DB .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1986, 108 (24) :7485-7488
[6]   NEAR-INFRARED RESONANCE RAMAN-SPECTROSCOPY OF THE SPECIAL PAIR AND THE ACCESSORY BACTERIOCHLOROPHYLLS IN PHOTOSYNTHETIC REACTION CENTERS [J].
CHEREPY, NJ ;
SHREVE, AP ;
MOORE, LJ ;
FRANZEN, S ;
BOXER, SG ;
MATHIES, RA .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (23) :6023-6029
[7]   Electronic and nuclear dynamics of the accessory bacteriochlorophylls in bacterial photosynthetic reaction centers from resonance Raman intensities [J].
Cherepy, NJ ;
Shreve, AP ;
Moore, LJ ;
Boxer, SG ;
Mathies, RA .
JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (16) :3250-3260
[8]   NEAR-INFRARED RESONANCE RAMAN-SPECTRA OF CHLOROFLEXUS-AURANTIACUS PHOTOSYNTHETIC REACTION CENTERS [J].
CHEREPY, NJ ;
HOLZWARTH, AR ;
MATHIES, RA .
BIOCHEMISTRY, 1995, 34 (15) :5288-5293
[9]   Near-infrared resonance Raman spectra of chlorosomes: Probing nuclear coupling in electronic energy transfer [J].
Cherepy, NJ ;
Du, M ;
Holzwarth, AR ;
Mathies, RA .
JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (11) :4662-4671
[10]   SCANNING MULTICHANNEL TECHNIQUE FOR IMPROVED SPECTROCHEMICAL MEASUREMENTS WITH A CCD CAMERA AND ITS APPLICATION TO RAMAN-SPECTROSCOPY [J].
DECKERT, V ;
KIEFER, W .
APPLIED SPECTROSCOPY, 1992, 46 (02) :322-328