The forces in the distal femur and the knee during walking and other activities measured by telemetry

被引:191
作者
Taylor, SJG
Walker, PS [1 ]
Perry, JS
Cannon, SR
Woledge, R
机构
[1] UCL, Royal Natl Orthopaed Hosp Trust, Ctr Biomed Engn, Stanmore HA7 4LP, Middx, England
[2] Royal Natl Orthopaed Hosp Trust, Inst Human Performance, Stanmore, Middx, England
关键词
total knee replacement; knee forces; telemetry;
D O I
10.1016/S0883-5403(98)90009-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The forces and moments in the shaft of a distal femoral replacement were measured by telemetry for a subject during different activities, and calculations were then made of the forces at the knee. The axial force showed a small peak at heel-strike followed by two main peaks during stance. In level walking, the peak axial force was between 1,487 and 1,718 N (2.2-2.5 BW), the peak shear force was 269-368 N (0.4-0.54 BW) directed anteriorly on the tibia, the peak axial torque was 7 Nm internal, while the patellofemoral force was 466-571 N. The highest axial force was recorded for descending stairs (2.8 BW). Standing on one leg produced 2.4 BW, while lying supine and raising the leg produced 1.7 BW. The data produced may resemble that of a normal subject, and has application to basic joint mechanics, to joint reconstruction, and to total knee replacement design and evaluation.
引用
收藏
页码:428 / 437
页数:10
相关论文
共 21 条
[1]  
ANDRIACCHI P, 1995, GAIT RESULTS INPUT D
[2]   WALKING SPEED AS A BASIS FOR NORMAL AND ABNORMAL GAIT MEASUREMENTS [J].
ANDRIACCHI, TP ;
OGLE, JA ;
GALANTE, JO .
JOURNAL OF BIOMECHANICS, 1977, 10 (04) :261-268
[3]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[4]   IS STAIRCASE WALKING A RISK FOR THE FIXATION OF HIP IMPLANTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (05) :535-553
[5]  
Brand R A, 1994, J Arthroplasty, V9, P45, DOI 10.1016/0883-5403(94)90136-8
[6]   NORMATIVE DATA OF KNEE-JOINT MOTION AND GROUND REACTION FORCES IN ADULT LEVEL WALKING [J].
CHAO, EY ;
LAUGHMAN, RK ;
SCHNEIDER, E ;
STAUFFER, RN .
JOURNAL OF BIOMECHANICS, 1983, 16 (03) :219-233
[7]   TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[8]  
Inman V. T., 1981, HUMAN WALKING, P89
[9]   MEASUREMENT OF LOWER-EXTREMITY KINEMATICS DURING LEVEL WALKING [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) :383-392
[10]   Instrumented implant for measuring tibiofemoral forces [J].
Kaufman, KR ;
Kovacevic, N ;
Irby, SE ;
Colwell, CW .
JOURNAL OF BIOMECHANICS, 1996, 29 (05) :667-671