Hemodialysis vascular access: Effect on urea kinetics and the dialysis prescription

被引:3
作者
Butterly, DW
Schwab, SJ
机构
[1] Department of Medicine, Division of Nephrology, Duke University Medical Center, Durham, NC
关键词
dialysis; vascular access; urea kinetic modeling;
D O I
10.1159/000168969
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The effective delivery of dialysis requires repeated reliable access to the central circulation capable of providing rapid blood flow. This access to the circulation continues to be the 'weak link' in the provision of long-term renal replacement therapy. Dialysis access malfunction is a major cause of inadequate dialysis delivery and venous stenosis is the leading cause of access malfunction and thrombosis. Careful monitoring of venous dialysis pressures and recirculation along with urea kinetic modeling and physical examination of the graft can prospectively identify the malfunctioning vascular access. When these indicators are used for referral for fistulogram, venous stenosis can be identified and corrected before graft thrombosis. Not only can preemptive repair of the vascular access prevent thrombosis, it also allows for more efficient dialysis delivery to the patient.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 32 条
  • [21] NEWMAN GE, 1991, J AM SOC NEPHROL, V2, pA341
  • [22] NONINVASIVE BLOOD-FLOW MEASUREMENT IN EXPANDED POLYTETRAFLUOROETHYLENE GRAFTS FOR HEMODIALYSIS ACCESS
    RITTGERS, SE
    GARCIAVALDEZ, C
    MCCORMICK, JT
    POSNER, MP
    [J]. JOURNAL OF VASCULAR SURGERY, 1986, 3 (04) : 635 - 642
  • [23] PREVENTION OF HEMODIALYSIS FISTULA THROMBOSIS - EARLY DETECTION OF VENOUS STENOSES
    SCHWAB, SJ
    RAYMOND, JR
    SAEED, M
    NEWMAN, GE
    DENNIS, PA
    BOLLINGER, RR
    [J]. KIDNEY INTERNATIONAL, 1989, 36 (04) : 707 - 711
  • [24] HEMODIALYSIS-ASSOCIATED SUBCLAVIAN VEIN STENOSIS
    SCHWAB, SJ
    QUARLES, LD
    MIDDLETON, JP
    COHAN, RH
    SAEED, M
    DENNIS, VW
    [J]. KIDNEY INTERNATIONAL, 1988, 33 (06) : 1156 - 1159
  • [25] SHACKLETON CR, 1987, CAN J SURG, V30, P442
  • [26] THE MEASUREMENT OF DIALYSIS ACCESS RECIRCULATION
    SHERMAN, RA
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 22 (04) : 616 - 621
  • [27] RATE-RELATED RECIRCULATION - THE EFFECT OF ALTERING BLOOD-FLOW ON DIALYZER RECIRCULATION
    SHERMAN, RA
    LEVY, SS
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1991, 17 (02) : 170 - 173
  • [28] HEMODYNAMICS OF FAILING DIALYSIS GRAFTS
    SULLIVAN, KL
    BESARAB, A
    BONN, J
    SHAPIRO, MJ
    GARDINER, GA
    MORITZ, MJ
    [J]. RADIOLOGY, 1993, 186 (03) : 867 - 872
  • [29] TWARDOWSKI ZJ, 1993, J AM SOC NEPHROL, V3, P1978
  • [30] A NEW VASCULAR ACCESS CATHETER FOR HEMODIALYSIS
    ULDALL, R
    DEBRUYNE, M
    BESLEY, M
    MCMILLAN, J
    SIMONS, M
    FRANCOEUR, R
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (03) : 270 - 277