Preliminary validation of a new standard of efficacy for stored platelets

被引:37
作者
AuBuchon, JP
Herschel, L
Roger, J
Murphy, S
机构
[1] Dartmouth Coll, Hitchcock Med Ctr, Dept Pathol, Lebanon, NH 03756 USA
[2] Dartmouth Coll, Hitchcock Med Ctr, Dept Med, Lebanon, NH 03756 USA
[3] Amer Red Cross, Blood Serv, Philadelphia, PA USA
关键词
D O I
10.1046/j.0041-1132.2004.00604.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Platelet preparation and storage systems, unlike those for RBC, lack an objective, absolute performance criterion to determine acceptability. Recently, a criterion based on paired comparison with the radiolabeled recovery and survival of "fresh" platelets has been proposed, namely, recovery = two-thirds and survival = half of "fresh" platelets. STUDY DESIGN AND METHODS: Eleven normal subjects donated a unit of leukoreduced apheresis platelets using a standard, approved system. They received an aliquot radiolabeled with In-111 or Cr-51 (random selection) 4 to 20 hours after donation and, using the other radioisotope, on Day 5 of storage. The recovery was calculated based on the injectate radioactivity. The survival was determined using the multiple-hit model. The area under the platelet survival curve was calculated using the COST program. RESULTS: Reinfusion of platelets less than 20 hours after collection resulted in a recovery of 74.7 +/- 12.3 percent and a survival time of 7.5 +/- 1.1 days. Reinfusion on Day 5 resulted in a recovery of 58.2 +/- 12.0 percent and a survival time of 6.9 +/- 1.4 days, values that were 77.9 +/- 9.5 percent and 91.8 +/- 16.1 percent of the observation using "fresh" platelets, respectively. The area under the curve using Day 5 platelets was 67.8 +/- 11.5 percent of that using "fresh" platelets. CONCLUSION: The proposed criterion for objective evaluation of platelet preparation and storage systems appears applicable to a commonly accepted approach, leukoreduced apheresis platelets stored in plasma for 5 days, and merits evaluation using other collection, treatment, and storage systems.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 18 条
[1]  
*AM ASS BLOOD BANK, 2001, STAND BLOOD BANKS TR
[3]   Experience with universal bacterial culturing to detect contamination of apheresis platelet units in a hospital transfusion service [J].
AuBuchon, JP ;
Cooper, LK ;
Leach, MF ;
Zuaro, DE ;
Schwartzman, JD .
TRANSFUSION, 2002, 42 (07) :855-861
[4]   Seven-day storage of single-donor platelets: recovery and survival in an autologous transfusion study [J].
Dumont, LJ ;
AuBuchon, JP ;
Whitley, P ;
Herschel, LH ;
Johnson, A ;
McNeil, D ;
Sawyer, S ;
Roger, JC .
TRANSFUSION, 2002, 42 (07) :847-854
[5]  
*FOOD DRUG ADM WOR, 2002, SAF EFF METH RED PAT
[6]  
HANSON SR, 1985, BLOOD, V66, P1105
[7]   CONCURRENT LABEL METHOD WITH IN-111 AND CR-51 ALLOWS ACCURATE EVALUATION OF PLATELET VIABILITY OF STORED PLATELET CONCENTRATES [J].
HOLME, S ;
HEATON, A ;
ROODT, J .
BRITISH JOURNAL OF HAEMATOLOGY, 1993, 84 (04) :717-723
[8]   Factors that influence platelet recovery after transfusion:: resolving donor quality from ABO compatibility [J].
Jiménez, TM ;
Patel, SB ;
Pineda, AA ;
Tefferi, A ;
Owen, WG .
TRANSFUSION, 2003, 43 (03) :328-334
[9]   A COMPUTER-PROGRAM IN COMPILED BASIC FOR THE IBM PERSONAL-COMPUTER TO CALCULATE THE MEAN PLATELET SURVIVAL-TIME WITH THE MULTIPLE-HIT AND WEIGHTED MEAN METHODS [J].
LOTTER, MG ;
RABE, WL ;
VANZYL, JM ;
HEYNS, AD ;
WESSELS, P ;
KOTZE, HF ;
MINNAAR, PC .
COMPUTERS IN BIOLOGY AND MEDICINE, 1988, 18 (04) :305-315
[10]   IN-VITRO ASSESSMENT OF THE QUALITY OF STORED PLATELET CONCENTRATES [J].
MURPHY, S ;
REBULLA, P ;
BERTOLINI, F ;
HOLME, S ;
MOROFF, G ;
SNYDER, E ;
STROMBERG, R .
TRANSFUSION MEDICINE REVIEWS, 1994, 8 (01) :29-36