Experience with universal bacterial culturing to detect contamination of apheresis platelet units in a hospital transfusion service

被引:72
作者
AuBuchon, JP [1 ]
Cooper, LK [1 ]
Leach, MF [1 ]
Zuaro, DE [1 ]
Schwartzman, JD [1 ]
机构
[1] Dartmouth Hitchcock Med Ctr, Dept Pathol, Lebanon, NH 03756 USA
关键词
D O I
10.1046/j.1537-2995.2002.00136.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Bacterial contamination of platelet units poses one of the greatest risks of morbidity and mortality to platelet transfusion recipients. A routine culture of all units (WBC-reduced apheresis platelet units) was instituted on Day 2 over a 2-year period to reduce this risk. STUDY DESIGN AND METHODS: A sterile connecting device was used to attach a small transfer pack on the morning of Day 2 after collection, and 10 mL of the unit were transferred to the small bag. After disconnection from the unit, about half of this volume was transferred to an aerobic culture bottle of an automated bacterial detection system. Units were maintained in available inventory until and unless a report was received of growth in the sample. When available, the unit or a retained aliquot was recultured if the initial sample was positive. Units were held up to 2 days beyond their 5-day outdate and used for transfusion if no other suitable units were available to meet the clinical need or were evaluated with in vitro testing on Day 8. RESULTS: Of 2678 units cultured, 16 (0.6%) were positive on initial culture. Thirteen could be recultured, and all of these samples were negative. Shortly after the 2-year period of the study, two units (split from the same collection) were documented as growing coagulase-negative Staphylococci 12 hours after sampling. Units transfused on Day 6 or 7 (n = 40) yielded expected clinical responses, and CCl available on 21 recipients 10 to 60 minutes after transfusion demonstrated acceptable results (mean, 14,400 8800; median, 12,191; 90% > 7500). More than 96 percent of units tested on Day 8 had pH greater than 6.2 and continued to demonstrate swirling. CONCLUSIONS: Routine culturing of apheresis platelet units is feasible, can be accomplished with a low rate of false positivity, and can detect contaminated units. The cost of such a protocol could be mitigated with extension of the storage period, and clinical experience with units held for 6 or 7 days was satisfactory.
引用
收藏
页码:855 / 861
页数:7
相关论文
共 48 条
[1]   SURVIVAL OF TRANSFUSED PLATELETS COLLECTED INTO NEW FORMULATION PLASTIC PACKS [J].
ARCHER, GT ;
GRIMSLEY, PG ;
JINDRA, J ;
ROBSON, JE ;
RIBEIRO, A .
VOX SANGUINIS, 1982, 43 (04) :223-230
[2]   THE EFFECTS OF PH AND AGITATION ON PLATELET PRESERVATION [J].
BANNAI, M ;
MAZDA, T ;
SASAKAWA, S .
TRANSFUSION, 1985, 25 (01) :57-59
[3]   STRATEGIES FOR THE AVOIDANCE OF BACTERIAL-CONTAMINATION OF BLOOD COMPONENTS [J].
BARRETT, BB ;
ANDERSEN, JW ;
ANDERSON, KC .
TRANSFUSION, 1993, 33 (03) :228-233
[4]   A multicenter inspection of the swirling phenomenon in platelet concentrates prepared in routine practice [J].
Bertolini, F ;
Murphy, S .
TRANSFUSION, 1996, 36 (02) :128-132
[5]   BACTERIAL-CONTAMINATION OF BLOOD PRODUCTS AND THE VALUE OF PRETRANSFUSION TESTING [J].
BLAJCHMAN, MA .
IMMUNOLOGICAL INVESTIGATIONS, 1995, 24 (1-2) :163-170
[6]   Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms [J].
Brecher, ME ;
Means, N ;
Jere, CS ;
Heath, D ;
Rothenberg, S ;
Stutzman, LC .
TRANSFUSION, 2001, 41 (04) :477-482
[7]  
Bruneau C, 1999, TRANSFUSION, V39, p116S
[8]   Rapid identification of bacterially contaminated platelets using reagent strips: Glucose and pH analysis as markers of bacterial metabolism [J].
Burstain, JM ;
Brecher, ME ;
Workman, K ;
Foster, M ;
Faber, GH ;
Mair, D .
TRANSFUSION, 1997, 37 (03) :255-258
[9]  
Castro EH, 1999, TRANSFUSION, V39, p75S
[10]  
Claeys H., 2000, VOX SANG S1, V78, P374