Evaluation of the cavotricuspid isthmus and right atrium by multidetector-row computed tomography in patients with common atrial flutter

被引:15
作者
Komatsu, S
Okuyama, Y
Omori, Y
Oka, T
Mizuno, H
Honda, T
Fujisawa, Y
Kiyomoto, M
Koshimune, Y
Higashide, T
Hirayama, A
Kodama, K
机构
[1] Osaka Police Hosp, Div Cardiovasc, Tennoji Ku, Osaka 5438502, Japan
[2] Osaka Univ, Grad Sch Med, Dept Internal Med & Therapeut, Osaka, Japan
[3] Osaka Police Hosp, Dept Radiol Technol, Osaka, Japan
关键词
atrial flutter; cavotricuspid isthmus; multidetector-row computed tomography; catheter ablation;
D O I
10.1007/s00380-005-0847-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The sizes of the right atrium ( RA), cavotricuspid isthmus, and Eustachian valve are predictors of success of radiofrequency catheter ablation for atrial flutter (AFL). We examined the relationship between the sizes of cavotricuspid isthmus as measured by multidetector-row computed tomography (MDCT) and fluoroscopy. We used eight-detector MDCT to measure the tricuspid isthmus of 23 patients prior to linear ablation for common AFL. One patient with a deep pouch in the RA was excluded. Parameters measured were (1) the length of the trace of isthmus (Ti), which was equivalent to the blocking line; (2) the size of the tricuspid isthmus (DTi); and (3) the distance from the tricuspid valve and inferior vena cava (IVC) (LDTi). DTi and LDTi indicate the size of the RA, reflecting the appropriately sized steerable ablation catheter, respectively. Of the 22 patients, 21 were ablated successfully without recurrence of AFL, and clinical success was achieved in one additional patient despite failure to obtain a bidirectional block. Ti, DTi, and LDTi were correlated with fluoroscopy time (r = 0.84, r = 0.88, and r = 0.88, respectively; P < 0.0001), total delivered energy (r = 0.81, r = 0.80, and r = 0.83, respectively; P < 0.0001), and application time (r = 0.84, r = 0.80, and r = 0.87, respectively; P < 0.0001). Measurement of the tricuspid isthmus by MDCT may noninvasively provide important information for successful linear ablation.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 24 条
[11]   Decreased pulmonary perfusion in pulmonary vein stenosis after radiofrequency ablation - Assessment with dynamic magnetic resonance perfusion imaging [J].
Kluge, A ;
Dill, T ;
Ekinci, O ;
Hansel, J ;
Hamm, C ;
Pitschner, HF ;
Bachmann, G .
CHEST, 2004, 126 (02) :428-437
[12]   Anatomical structure of the isthmus between the inferior vena cava and tricuspid annulus investigated with a three-dimensional electroanatomical mapping system [J].
Kubo, R ;
Shoda, M ;
Fuda, Y ;
Sugiura, R ;
Kasanuki, H .
HEART AND VESSELS, 2005, 20 (02) :50-55
[13]   RADIOFREQUENCY CATHETER ABLATION OF ATRIAL ARRHYTHMIAS - RESULTS AND MECHANISMS [J].
LESH, MD ;
VANHARE, GF ;
EPSTEIN, LM ;
FITZPATRICK, AP ;
SCHEINMAN, MM ;
LEE, RJ ;
KWASMAN, MA ;
GROGIN, HR ;
GRIFFIN, JC .
CIRCULATION, 1994, 89 (03) :1074-1089
[14]   CYANOSIS IN ATRIAL SEPTAL-DEFECT DUE TO PERSISTENT EUSTACHIAN VALVE [J].
MORISHITA, Y ;
YAMASHITA, M ;
YAMADA, K ;
ARIKAWA, K ;
TAIRA, A .
ANNALS OF THORACIC SURGERY, 1985, 40 (06) :614-616
[15]   Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter [J].
Nakagawa, H ;
Jackman, WM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06) :1279-1286
[16]   Complex atrial reentrant circuits evaluated by entrainment mapping using a multielectrode basket catheter [J].
Nishida, K ;
Fujiki, A ;
Nagasawa, H ;
Sakabe, M ;
Mizumaki, K ;
Inoue, H ;
Misaki, T .
CIRCULATION JOURNAL, 2004, 68 (02) :168-171
[17]   Influence of right atrial structure on outcome of radiofrequency catheter ablation for common atrial flutter [J].
Ohba, Y ;
Shimoike, E ;
Ueda, N ;
Maruyama, T ;
Kaji, Y ;
Fujino, T ;
Niho, Y .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (10) :741-744
[18]   Clinical study of the efficacy of a cooled-tip catheter ablation system for common atrial flutter [J].
Okishige, K ;
Aonuma, K ;
Yamauchi, Y ;
Azegami, K ;
Suzuki, K ;
Isobe, M ;
Iesaka, Y .
CIRCULATION JOURNAL, 2004, 68 (01) :73-76
[19]   DEMONSTRATION OF AN AREA OF SLOW CONDUCTION IN HUMAN ATRIAL-FLUTTER [J].
OLSHANSKY, B ;
OKUMURA, K ;
HESS, PG ;
WALDO, AL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (07) :1639-1648
[20]   Transcatheter angioplasty for acquired pulmonary vein stenosis after radiofrequency ablation [J].
Qureshi, AM ;
Prieto, LR ;
Latson, LA ;
Lane, GK ;
Mesia, CI ;
Radvansky, P ;
White, RD ;
Marrouche, NF ;
Saad, EB ;
Bash, DL ;
Natale, A ;
Rhodes, JF .
CIRCULATION, 2003, 108 (11) :1336-1342