Extremes of body mass index do not impact mid-term survival after continuous-flow left ventricular assist device implantation

被引:44
作者
Brewer, Robert J. [1 ]
Lanfear, David E. [1 ]
Sai-Sudhakar, Chittoor B. [2 ]
Sundareswaran, Kartik S. [3 ]
Ravi, Yazhini [2 ]
Farrar, David J. [3 ]
Slaughter, Mark S. [4 ]
机构
[1] Henry Ford Hosp, Inst Heart & Vasc, Detroit, MI 48202 USA
[2] Ohio State Univ, Dept Surg, Columbus, OH 43210 USA
[3] Thoratec Corp, Pleasanton, CA USA
[4] Univ Louisville, Dept Surg, Louisville, KY 40292 USA
关键词
left ventricular assist device; body mass index; cachexia; obesity; outcomes; HEART-FAILURE; OUTCOMES; PLACEMENT;
D O I
10.1016/j.healun.2011.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Extremes of body mass index (BMI) are often considered contraindications to use of a left ventricular assist device (LVAD), but data regarding outcomes across the spectrum of BMI are limited. We sought to assess the association of BMI with survival and major morbidity after continuous-flow (CF) LVAD implantation. METHODS: Patients (n = 896) enrolled in the HeartMate II LVAD bridge-to-transplantation and destination therapy trials were divided into 4 BMI groups: underweight (< 18.5 kg/m(2)); normal (18.5 kg/m(2) <= BMI < 30 kg/m(2)); obese (30 kg/m(2) <= BMI < 35 kg/m(2)); and extremely obese (>= 35 kg/m(2)). The association of BMI with survival was tested using Kaplan-Meier analysis and proportional hazards regression. Major adverse events were compared using Poisson's regression and chi-square tests. RESULTS: At implantation, 48(5%) patients were underweight, 596(67%) normal weight, 164(18%) obese and 88 (10%) extremely obese. BMI extremes were associated with differences in creatinine, albumin, age, central venous pressure and etiology. BMI was not associated with survival in the univariate analysis (p = 0.83) or in adjusted models (extremely obese: hazard ratio [HR] 1.29, p = 0.231; obese: HR 0.94, p = 0.723; underweight: HR 1.23, p = 0.452). Underweight patients were more likely to have bleeding events (p < 0.001), whereas extremely obese patients had higher rates of device-related infection (p = 0.041) and rehospitalization (p = 0.014). CONCLUSIONS: Overall survival in patients receiving CF LVAD is similar across BMI categories. Carefully selected patients at both extremes of BMI have good mid-term survival after LVAD and should be considered for LVAD implantation relative to overall risk profile. J Heart Lung Transplant 2012;31:167-72 (C) 2012 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 11 条
[1]   Body mass index and outcomes after left ventricular assist device placement [J].
Butler, J ;
Howser, R ;
Portner, PM ;
Pierson, RN .
ANNALS OF THORACIC SURGERY, 2005, 79 (01) :66-73
[2]   Ventricular assist device in severe heart failure - Effects on cytokines, complement and body weight [J].
Clark, AL ;
Leobe, M ;
Potapov, EV ;
Egerer, K ;
Knosalla, C ;
Hetzer, R ;
Anker, SD .
EUROPEAN HEART JOURNAL, 2001, 22 (24) :2275-2283
[3]   Destination Therapy: One-Year Outcomes in Patients With a Body Mass Index Greater Than 30 [J].
Coyle, Laura A. ;
Ising, Mickey S. ;
Gallagher, Colleen ;
Bhat, Geetha ;
Kurien, Sudha ;
Sobieski, Michael A. ;
Slaughter, Mark S. .
ARTIFICIAL ORGANS, 2010, 34 (02) :93-97
[4]   Pathophysiology and treatment options for cardiac anorexia [J].
Fudim M. ;
Wagman G. ;
Altschul R. ;
Yucel E. ;
Bloom M. ;
Vittorio T.J. .
Current Heart Failure Reports, 2011, 8 (2) :147-153
[5]   Continuous Flow Left Ventricular Assist Device Outcomes in Commercial Use Compared With the Prior Clinical Trial [J].
John, Ranjit ;
Naka, Yoshifumi ;
Smedira, Nicholas G. ;
Starling, Randall ;
Jorde, Ulrich ;
Eckman, Peter ;
Farrar, David J. ;
Pagani, Francis D. .
ANNALS OF THORACIC SURGERY, 2011, 92 (04) :1406-1412
[6]   Body Mass Index is a Useful Predictor of Prognosis After Left Ventricular Assist System Implantation [J].
Mano, Akiko ;
Fujita, Kiyoharu ;
Uenomachi, Kaori ;
Kazama, Keiichi ;
Katabuchi, Mayumi ;
Wada, Kyoichi ;
Terakawa, Nobue ;
Arai, Koji ;
Hori, Yumiko ;
Hashimoto, Syuji ;
Nakatani, Takeshi ;
Kitamura, Soichiro .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (05) :428-433
[7]   Effect of body mass index and device type on infection in left ventricular assist device support beyond 30 days [J].
Martin, Stanley I. ;
Wellington, Linda ;
Stevenson, Kurt B. ;
Mangino, Julie E. ;
Sai-Sudhakar, Chittoor B. ;
Firstenberg, Michael S. ;
Blais, Danielle ;
Sun, Benjamin C. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 11 (01) :20-23
[8]   Use of a continuous-flow device in patients awaiting heart transplantation [J].
Miller, Leslie W. ;
Pagani, Francis D. ;
Russell, Stuart D. ;
John, Ranjit ;
Boyle, Andrew J. ;
Aaronson, Keith D. ;
Conte, John V. ;
Naka, Yoshifumi ;
Mancini, Donna ;
Delgado, Reynolds M. ;
MacGillivray, Thomas E. ;
Farrar, David J. ;
Frazier, O. H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (09) :885-896
[9]   Body mass index and outcome after ventricular assist device placement [J].
Musci, Michele ;
Loforte, Antonio ;
Potapov, Evgenij V. ;
Krabatsch, Thomas ;
Weng, Yuguo ;
Pasic, Miralem ;
Hetzer, Roland .
ANNALS OF THORACIC SURGERY, 2008, 86 (04) :1236-1242
[10]   Obesity and Left Ventricular Assist Device Driveline Exit Site Infection [J].
Raymond, Ashley L. ;
Kfoury, Abdallah G. ;
Bishop, Corey J. ;
Davisj, Erin S. ;
Goebel, Kimberly M. ;
Stoker, Sandi ;
Selzman, Craig H. ;
Clayson, Stephen E. ;
Smith, Hildegard ;
Cowley, Cris G. ;
Alharethi, Rami ;
Budge, Deborah ;
Reid, Bruce B. .
ASAIO JOURNAL, 2010, 56 (01) :57-60