Continuous Flow Left Ventricular Assist Device Outcomes in Commercial Use Compared With the Prior Clinical Trial

被引:91
作者
John, Ranjit [1 ]
Naka, Yoshifumi
Smedira, Nicholas G.
Starling, Randall
Jorde, Ulrich
Eckman, Peter
Farrar, David J.
Pagani, Francis D.
机构
[1] Univ Minnesota, Div Cardiothorac Surg, Minneapolis, MN 55455 USA
关键词
MECHANICAL CIRCULATORY SUPPORT; TRANSPLANT; SYSTEMS; BRIDGE;
D O I
10.1016/j.athoracsur.2011.05.080
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background. A multicenter clinical trial conducted from 2005 to 2008 of a continuous flow left ventricular assist device (LVAD) resulted in Food and Drug Administration approval for bridge to transplantation. The purpose of this analysis was to determine changes in posttrial outcomes in widespread commercial use since the clinical trial. Methods. We compared outcomes of 486 patients who received a continuous flow LVAD as a bridge to transplantation at 36 centers during the clinical trial (March 2005 to April 2008) with outcomes of 1,496 posttrial patients who received a continuous flow LVAD at 83 centers (April 2008 to September 2010 as reported to the Interagency Registry for Mechanically Assisted Circulatory Support). Results. Baseline data were comparable between groups. Cumulative follow-up was 511 and 1,082 patient-years for trial and posttrial patients, respectively, and average support duration was 12.6 +/- 14.0 and 8.7 +/- 7.1 months. Kaplan-Meier survival improved at 1 year from 76% (trial) to 85% (posttrial). The percentage of patients undergoing transplantation in the first year decreased from 48% in the trial period to 39% in the posttrial period. Quality of life metrics improved by 3 months in both groups. Conclusions. The survival rate of a large group of continuous flow LVAD patients in a real-world setting after Food and Drug Administration market approval for bridge to transplantation has improved since the clinical trial. These data show that excellent outcomes have been maintained with dissemination of new LVAD technology from a clinical trial phase to more broad based use in the period after market approval. (Ann Thorac Surg 2011;92:1406-13) (C) 2011 by The Society of Thoracic Surgeons
引用
收藏
页码:1406 / 1412
页数:7
相关论文
共 24 条
[1]
Low Thromboembolism and Pump Thrombosis With the HeartMate II Left Ventricular Assist Device: Analysis of Outpatient Anti-coagulation [J].
Boyle, Andrew J. ;
Russell, Stuart D. ;
Teuteberg, Jeffrey J. ;
Slaughter, Mark S. ;
Moazami, Nader ;
Pagani, Francis D. ;
Frazier, O. Howard ;
Heatley, Gerald ;
Farrar, David J. ;
John, Ranjit .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (09) :881-887
[2]
The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients [J].
Cowger, Jennifer ;
Pagani, Francis D. ;
Haft, Jonathan W. ;
Romano, Matthew A. ;
Aaronson, Keith D. ;
Kolias, Theodore J. .
CIRCULATION-HEART FAILURE, 2010, 3 (06) :668-674
[3]
Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[4]
Rise of the Machines - Left Ventricular Assist Devices as Permanent Therapy for Advanced Heart Failure [J].
Fang, James C. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23) :2282-2285
[5]
Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy [J].
John, Ranjit ;
Kamdar, Forum ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Boyle, Andrew ;
Joyce, Lyle .
ANNALS OF THORACIC SURGERY, 2008, 86 (04) :1227-1235
[6]
Aortic valve pathophysiology during left ventricular assist device support [J].
John, Ranjit ;
Mantz, Katie ;
Eckman, Peter ;
Rose, Alan ;
May-Newman, Karen .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (12) :1321-1329
[7]
Activation of Endothelial and Coagulation Systems in Left Ventricular Assist Device Recipients [J].
John, Ranjit ;
Panch, Sandhya ;
Hrabe, Jennifer ;
Wei, Peng ;
Solovey, Anna ;
Joyce, Lyle ;
Hebbel, Robert .
ANNALS OF THORACIC SURGERY, 2009, 88 (04) :1171-1179
[8]
Low thromboembolic risk for patients with the Heartmate II left ventricular assist device [J].
John, Ranjit ;
Kamdar, Forum ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Miller, Leslie ;
Joyce, Lyle ;
Boyle, Andrew .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (05) :1318-1323
[9]
Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device [J].
Letsou, GV ;
Shah, N ;
Gregoric, ID ;
Myers, TJ ;
Delgado, R ;
Frazier, OH .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (01) :105-109
[10]
Use of a continuous-flow device in patients awaiting heart transplantation [J].
Miller, Leslie W. ;
Pagani, Francis D. ;
Russell, Stuart D. ;
John, Ranjit ;
Boyle, Andrew J. ;
Aaronson, Keith D. ;
Conte, John V. ;
Naka, Yoshifumi ;
Mancini, Donna ;
Delgado, Reynolds M. ;
MacGillivray, Thomas E. ;
Farrar, David J. ;
Frazier, O. H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (09) :885-896