Predictive value of the index of microcirculatory resistance in patients with ST-segment elevation myocardial infarction

被引:293
作者
Fearon, William F. [1 ]
Shah, Maulik [1 ]
Ng, Martin [1 ]
Brinton, Todd [1 ]
Wilson, Andrew [1 ]
Trernmel, Jennifer A. [1 ]
Schnittger, Ingela [1 ]
Lee, David P. [1 ]
Vagelos, Randall H. [1 ]
Fitzgerald, Peter J. [1 ]
Yock, Paul G. [1 ]
Yeung, Alan C. [1 ]
机构
[1] Stanford Univ, Med Ctr, Div Cardiovasc Med, Stanford, CA 94305 USA
关键词
D O I
10.1016/j.jacc.2007.08.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The objective of this study is to evaluate the predictive value of the index of microcirculatory resistance (IMR) in patients undergoing primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Background Despite adequate epicardial artery reperfusion, a number of patients with STEMI have a poor prognosis because of microvascular damage. Assessing the status of the microvasculature in this setting remains challenging. Methods In 29 patients after primary PCI for STEMI, IMR was measured with a pressure sensor/thermistor-tipped guide-wire. The Thrombolysis In Myocardial Infarction (TIMI) myocardial perfusion grade, TIMI frame count, coronary flow reserve, and ST-segment resolution were also recorded. Results The IMR correlated significantly with the peak creatinine kinase (CK) (R = 0.61, p = 0.0005) while the other measures of microvascular dysfunction did not. In patients with an IMR greater than the median value of 32 U, the peak CK was significantly higher compared with those having values <= 32 U (3,128 +/- 1,634 ng/ml vs. 1,201 +/- 911 ng/ml, p = 0.002). The IMR correlated significantly with 3-month echocardiographic wall motion score (WMS) (R = 0.59, p = 0.002) while the other measures of microvascular function did not. The WMS at 3-month follow-up was significantly worse in the group with an IMR >32 U compared with <= 32 U (28 +/- 7 vs. 20 +/- 4, p = 0.001). On multivariate analysis, IMR was the strongest predictor of peak CK and 3-month WMS. The IMR was the only significant predictor of recovery of left ventricular function on the basis of the percent change in WMS (R = 0.50, p < 0.01). Conclusions Compared to standard measures, IMR appears to be a better predictor of microvascular damage after STEMI, both acutely and in short term follow-up.
引用
收藏
页码:560 / 565
页数:6
相关论文
共 24 条
[1]   Epicardial stenosis severity does not affect minimal microcirculatory resistance [J].
Aarnoudse, W ;
Fearon, WF ;
Manoharan, G ;
Geven, M ;
van de Vosse, F ;
Rutten, M ;
De Bruyne, B ;
Pijls, NHJ .
CIRCULATION, 2004, 110 (15) :2137-2142
[2]   Myocardial resistance assessed by guidewire-based pressure-temperature measurement: In vitro validation [J].
Aarnoudse, W ;
van den Berg, P ;
van de Vosse, F ;
Geven, M ;
Rutten, M ;
van Turnhout, M ;
Fearon, W ;
De Bruyne, B ;
Pijls, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (01) :56-63
[3]   Rheolytic thrombectomy with percutaneous coronary intervention for infarct size reduction in acute myocardial infarction - 30-day results from a multicenter randomized study [J].
Ali, Arshad ;
Cox, David ;
Dib, Nabil ;
Brodie, Bruce ;
Berman, Daniel ;
Gupta, Navin ;
Browne, Kevin ;
Iwaoka, Robert ;
Azrin, Michael ;
Stapleton, Dwight ;
Setum, Cindy ;
Popma, Jeffrey .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) :244-252
[4]   Medical progress - Coronary microvascular dysfunction [J].
Camici, Paolo G. ;
Crea, Filippo .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (08) :830-840
[5]   Coronary thermodilution to assess flow reserve - Experimental validation [J].
De Bruyne, B ;
Pijls, NHJ ;
Smith, L ;
Wievegg, M ;
Heyndrickx, GR .
CIRCULATION, 2001, 104 (17) :2003-2006
[6]   ST segment resolution as a tool for assessing the efficacy of reperfusion therapy [J].
de Lemos, JA ;
Braunwald, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (05) :1283-1294
[7]   Simultaneous coronary pressure and flow velocity measurements in humans - Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve [J].
deBruyne, B ;
Bartunek, J ;
Sys, SU ;
Pijls, NHJ ;
Heyndrickx, GR ;
Wijns, W .
CIRCULATION, 1996, 94 (08) :1842-1849
[8]   Microvascular resistance is not influenced by epicardial coronary artery stenosis severity - Experimental validation [J].
Fearon, WF ;
Aarnoudse, W ;
Pijls, NHJ ;
De Bruyne, B ;
Balsam, LB ;
Cooke, DT ;
Robbins, RC ;
Fitzgerald, PJ ;
Yeung, AC ;
Yock, PG .
CIRCULATION, 2004, 109 (19) :2269-2272
[9]   Comparison of coronary thermodilution and Doppler velocity for assessing coronary flow reserve [J].
Fearon, WF ;
Farouque, HMO ;
Balsam, LB ;
Cooke, DT ;
Robbins, RC ;
Fitzgerald, PJ ;
Yeung, AC ;
Yock, PG .
CIRCULATION, 2003, 108 (18) :2198-2200
[10]   Novel index for invasively assessing the coronary microcirculation [J].
Fearon, WF ;
Balsam, LB ;
Farouque, HMO ;
Robbins, RC ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 107 (25) :3129-3132